{\rtf1\ansi \deff159\deflang1033{\fonttbl{\f3\fmodern\fcharset0\fprq1 Courier;}{\f15\froman\fcharset0\fprq2 CG Times;}{\f159\froman\fcharset0\fprq0 CG Times (WN);}}{\colortbl;\red0\green0\blue0;\red0\green0\blue255; \red0\green255\blue255;\red0\green255\blue0;\red255\green0\blue255;\red255\green0\blue0;\red255\green255\blue0;\red255\green255\blue255;\red0\green0\blue128;\red0\green128\blue128;\red0\green128\blue0;\red128\green0\blue128;\red128\green0\blue0; \red128\green128\blue0;\red128\green128\blue128;\red192\green192\blue192;}{\stylesheet{\widctlpar \f159 \snext0 Normal;}{\*\cs10 \additive Default Paragraph Font;}{\s34\widctlpar\tqc\tx4320\tqr\tx8640 \f159 \sbasedon0\snext34 footer;}{ \s35\widctlpar\tqc\tx4320\tqr\tx8640 \f159 \sbasedon0\snext35 header;}}{\info{\title \'09THIS SECTION MAY ALSO BE LOCATED UNDER}{\author A.R.Raia}{\operator Erol Fox}{\creatim\yr1994\mo7\dy22\hr12\min13}{\revtim\yr1997\mo6\dy12\hr13\min49}{\version3} {\edmins0}{\nofpages9}{\nofwords3133}{\nofchars17860}{\*\company CADSPEC Multimedia}{\vern57431}}\margl1440\margr1440\margb1080 \widowctrl\ftnbj\aenddoc\hyphhotz0\noextrasprl\prcolbl\cvmme\sprsspbf\brkfrm\swpbdr\hyphcaps0\fracwidth \fet0\sectd \linex0\endnhere {\footer \pard\plain \s34\widctlpar\tqc\tx4320\tqr\tx8640 \f159 {\b\fs18 SPECCSIC.DOC }{\field{\*\fldinst page }{\fldrslt {\lang1024 9}}}{\b\fs18 } \par }{\*\pnseclvl1\pnucrm\pnstart1\pnindent720\pnhang{\pntxta .}}{\*\pnseclvl2\pnucltr\pnstart1\pnindent720\pnhang{\pntxta .}}{\*\pnseclvl3\pndec\pnstart1\pnindent720\pnhang{\pntxta .}}{\*\pnseclvl4\pnlcltr\pnstart1\pnindent720\pnhang{\pntxta )}}{\*\pnseclvl5 \pndec\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl6\pnlcltr\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl7\pnlcrm\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl8\pnlcltr\pnstart1\pnindent720\pnhang {\pntxtb (}{\pntxta )}}{\*\pnseclvl9\pnlcrm\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}\pard\plain \widctlpar\tqr\tx9090 \f159 {\b\i\f3\fs20 [Notes and comments are shown in italics. These should be removed before printing this specification. References to CORIAN\'ae Surfaces drawings and bulletins can be retained for a closed CORIAN spec but should be removed for an open spec.) \par \tab \par }\pard \li3510\ri-180\widctlpar\tqr\tx9090 {\b\i\f3\fs20 [}{\i\f3\fs20 THIS SECTION MAY ALSO BE LOCATED UNDER \par \tab MASTERFORMAT HEADING 09540, "SPECIAL SURFACES." }{\b\i\f3\fs20 ] \par }\pard \qc\widctlpar\tqr\tx9090 {\b\f3\fs20 \par }{\b\fs28 SECTION 06650 \par SOLID POLYMER FABRICATIONS \par }\pard \widctlpar\tqr\tx9090 {\b \par I. GENERAL \par \par }\trowd \trgaph108\trleft-108\trkeep \cellx9252 \pard \widctlpar\intbl\tqr\tx9090 {\b 1.01 DESCRIPTION\cell }\pard \widctlpar\intbl {\b \row }\pard \li360\widctlpar\tqr\tx9090 {\i\fs20 [ADD TO OR DELETE PER PROJECT REQUIREMENTS] \par }\pard \li720\widctlpar\tqdec\tx1080\tx1440\tqr\tx9090 {\b \par }{\b\ul A. Work described in this section: \par }{\b \tab \par \tab 1.\tab Tub and shower walls \par \tab 2.\tab Toilet & Shower partitions \par \tab 3.\tab Wall cladding/wainscoting \par \tab 4.\tab Bumper rails \par \tab 5.\tab Interior steps \par \tab 6.\tab Seats \par \tab 7.\tab Laboratory countertops \par \tab 8.\tab Reception areas/nurses' stations \par \tab 9.\tab Table tops \par \tab 10.\tab Bar tops \par \tab 11.\tab Cold cafeteria surfaces \par \tab 12.\tab Hot cafeteria surfaces \par \tab 13.\tab Countertops with sinks \par \tab 14.\tab Free standing island countertops with sinks \par \tab 15.\tab Lavatory tops with seamed bowls \par \tab 16.\tab Lavatory tops with undermount bowls \par \tab 17.\tab Lavatory tops with integral bowls \par \tab 18.\tab Window sills \par \tab 19.\tab Thermoforming \par \tab 20.\tab Cove backsplashes \par \tab 21.\tab Color inlays \par \par }{\b\ul B. Related work specified elsewhere: \par }{\b \par \tab 1.\tab (Finish carpentry.)(Architectural woodwork.) \par \tab 2.\tab Tile work. \par \tab 3.\tab Wall coverings. \par \tab 4.\tab Casework. \par \tab 5.\tab Plumbing. \par \par \par }\pard \qc\li720\widctlpar\tqdec\tx1080\tx1440\tqr\tx9090 {\b \par }\trowd \trgaph108\trleft-108\trkeep \cellx9252 \pard \widctlpar\intbl\tqdec\tx1080\tx1440\tqr\tx9090 {\b 1.02 REFERENCES\cell }\pard \widctlpar\intbl {\b \row }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx9324 \pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 A.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Applicable Standards: Standards of the following, as referenced herein: \par 1. American National Standards Institute (ANSI) \par 2. American Society for Testing and Materials (ASTM) \par 3. National Electrical Manufacturers Association (NEMA) \par 4. Federal Specifications (FS)\cell }\pard \widctlpar\intbl {\b \row }\pard \li720\widctlpar\tqdec\tx1080\tx1440\tqr\tx9090 {\b \par }\trowd \trgaph108\trleft-108\trkeep \cellx9252 \pard \widctlpar\intbl\tqdec\tx1080\tx1440\tqr\tx9090 {\b 1.03 SUBMITTALS\cell }\pard \widctlpar\intbl {\b \row }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx9324 \pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 A.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Shop drawings: Indicate dimensions, component sizes, fabrication details, attachment provisions and coordination requirements with adjacent work.\cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 B.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Samples: Submit minimum 2" x 2" (50 mm x 50 mm) samples. Indicate full range of color and pattern variation. Approved samples will be retained as standards for work.\cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 { \b\fs22 C.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Product data: Indicate product description, fabrication information and compliance with specified performance requirements.\cell }\pard \widctlpar\intbl {\b \row }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx9324 \pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 D.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Maintenance data: Submit manufacturer's care and maintenance data, including repair and cleaning instructions. Include in project close-out documents.\cell }\pard \widctlpar\intbl {\b \row }\pard \widctlpar\tqr\tx9090 {\b \par }\trowd \trgaph108\trleft-108\trkeep \cellx9252 \pard \widctlpar\intbl\tqr\tx9090 {\b 1.04 QUALITY ASSURANCE\cell }\pard \widctlpar\intbl {\b \row }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx8964 \pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 A.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Allowable tolerances: \par 1. Variation in component size: }{\field\flddirty{\*\fldinst {\b\fs22 symbol 177 \\f "Symbol"}}{\fldrslt }}{\b\fs22 1/8" (3 mm). \par 2. Location of openings: }{\field\flddirty{\*\fldinst {\b\fs22 symbol 177 \\f "Symbol"}}{\fldrslt }}{\b\fs22 1/8" (3 mm) from indicated location.\cell }\pard \widctlpar\intbl {\b \row }\pard \widctlpar\tqr\tx9090 {\b \par }\trowd \trgaph108\trleft-108\trkeep \cellx9252 \pard \widctlpar\intbl\tqr\tx9090 {\b 1.05 DELIVERY, STORAGE AND HANDLING\cell }\pard \widctlpar\intbl {\b \row }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx9324 \pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 A.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Deliver no components to project site until areas are ready for installation. Store components indoors prior to installation.\cell }\pard \widctlpar\intbl {\b \row }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx9324 \pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 B.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Handle materials to prevent damage to finished surfaces. Provide protective coverings to prevent physical damage or staining following installation for duration of project.\cell }\pard \widctlpar\intbl {\b \row }\pard \widctlpar\tqr\tx9090 {\b \par }\trowd \trgaph108\trleft-108\trkeep \cellx9252 \pard \widctlpar\intbl\tqr\tx9090 {\b 1.06 WARRANTY\cell }\pard \widctlpar\intbl {\b \row }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx9324 \pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 A.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Provide manufacturer\rquote s 10 year warranty against defects in materials. Warranty shall provide material and labor to repair or replace defective materials. Damage caused by physical or chemical abuse or damage from excessive heat will not be warranted.}{\b\i\fs22 [}{\i\fs22 An extended warranty }{\i\fs22\up6 (1)}{\i\fs22 which includes fabrication and installation performance is available}{\b\i\fs22 .]}{\b\fs22 \cell }\pard \widctlpar\intbl {\b \row }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx9324 \pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 B.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 This Warranty }{\b\i\fs22 [}{\i\fs22\up6 (1)}{\b\i\fs22 ]}{\b\fs22 applies to [Commercially] [Residentially] installed CORIAN Products: \par 1. Purchased after January 1, 1987, for use in the United States, Canada, or Mexico \par 2. Which are maintained according to the DuPont CORIAN Care and Maintenance \par brochure (H-47338) and the Commercial or Residential Care and Maintenance \par Video. A copy may be obtained, free of charge, from your DuPont Certified \par Fabrication/Installation Source or by calling DuPont at 1-800-4CORIAN \par (1-800-426-7426). \par Refer to the [Commercial][Residential] Warranty Card[}{\fs22 s}{\b\fs22 ] for complete details. \par }{\b\fs22\up6 \par }{\b\i\fs22\up6 [}{\i\fs22\up6 (1)}{\i\fs22 To qualify for the optional Installed Warranty, fabrication and installation must be performed by a DuPont Certified Fabrication / Installation Source who will provide a brand plate for the application. This warranty covers all fabrication and installat ion performed by the Certified/Approved Source subject to the specific wording contained in the Installed Warranty Card}{\b\i\fs22 .]}{\b\fs22 \cell }\pard \widctlpar\intbl {\b \row }\pard \widctlpar\tqr\tx9090 {\b \par II. PRODUCTS \par \par }\trowd \trgaph108\trleft-108\trkeep \cellx9252 \pard \widctlpar\intbl\tqr\tx9090 {\b 2.01 SOLID POLYMER FABRICATIONS\cell }\pard \widctlpar\intbl {\b \row }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx9324 \pard \li216\widctlpar\intbl\tqr\tx9090 { \b\fs22 A.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Specified product: CORIAN\'ae SURFACES from The DuPont Company\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 \cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 \cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 \cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\i\fs20 [}{\i\fs20 RETAIN BELOW FOR PERFORMANCE SPECIFICATION}{\b\i\fs20 ] \cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 \cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 \cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 B.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Material: Homogeneous filled acrylic; not coated, laminated or of composite construction; meeting ANSI Z124.3 & .6, Type Six, and Fed. Spec. WW-P-541E/GEN. \par 1. Material shall have minimum physical and performance properties specified in the \par following Section U. \par 2. Superficial damage to a depth of 0.010" (,25 mm) shall be repairable by sanding and \par polishing.\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 C.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Tub and shower walls; 1/4" (6 mm) thick , standard panels of CORIAN, consisting of four 1/4" x 57" x 29 5/16", ___________ color. (Technical Bulletin H-20371, H-03836, Technical Drawing: MASON1, WETWALLS, DRYWALLS, WETWLNGS)\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 D.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Toilet and Shower partitions: Panels and pilasters of 3/4" (19 mm) thick CORIAN, __________ color. Pilasters attached at floor and ceiling. Provide with hardware for attachment of panels to pilasters as indicated on the Architect's Drawings. (Technica l Bulletin: H-03836)\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 E.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Wall cladding / wainscoting , 1/4" (6 mm) thick, with [ butt joints] or [1/8" (3 mm) wide joints] sealed with color matching Silicone Sealant for DuPont CORIAN; adhesively applied to solid substrates; ___________ color.\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 F.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Bumper rails: Fabricated of [1/2"(13 mm)][3/4\rdblquote (19mm)] CORIAN to size and shape with edge details as specified on the Architect\rquote s Drawings; adhesively joined with inconspicuous seams; __________ color. Install bumper rails without exposed fasteners. \cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 G.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Interior Steps: Stringers of 1" plywood, one on each end, ot hers as needed to provide 12" maximum spacing between stringers. Stringer ends to be covered with [1/4" (6 mm)][1/2" (13 mm)] thick CORIAN; _______ color. Tread of 1/2" (13 mm) thick CORIAN; sand with 120 grit sandpaper; _______ color. Horizontal suppo rt of 1" plywood. Riser of 1/4" (6 mm) thick CORIAN; ________ color, with vertical kicker (typically 1/4" plywood.) Details are for up to 3 steps only. Larger assemblies require 2" x 12" stringers as specified on the Architect\rquote s Drawings. \par (Technical Drawing:STEPS)\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 H.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Seats: Seating surfaces of [(1/2" (13 mm)][3/4\rdblquote (19mm)] thick CORIAN; _______ color. Attach to support structure with silicone sealant and/or thru bolts as specified on the Architect\rquote s Drawings. [Technical Drawing: SEATS]\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 I.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Laboratory countertops: [1/2" (13 mm)] [3/4" (19 mm)] thick CORIAN, adhesively joined with inconspicuous seams; edge details as specified on the Architect \rquote s Drawings; ________ color; [complete with specified bowls]. Surfaces to be unaffected by Class I reage nts and repairable after exposure to Class II reagents.( [Architect Note - See DuPont literature on CORIAN for list of typical Class I and Class II reagents.](Technical Bulletin: H-16309)\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 J.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Reception areas/nurses' stations: Horizontal surfaces of [1/2" (13 mm)][3/4" (19 mm)] thick CORIAN adhesively joined with inconspicuous seams; edge details as indicated on the Architect\rquote s Drawings; ________ color. Vertical surfaces shall be [1/4" (6 mm)][1/2" (13 mm)][3/4" 919 mm)] material as shown on the Architect\rquote s Drawings;}{\b\fs22\ul _______}{\b\fs22 color.\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 K.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Table tops: [1/2" (13 mm)][3/4" (19 mm)] thick CORIAN, adhesively joined with inconspicuous seams; edge details as indicated on the Architect\rquote s Drawings; ___________ color. [Technical Bulletin: H-26278]\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 L.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Bar tops: [1/2" (13 mm)][3/4"(19 mm)] thick CORIAN, adhesively joined with inconspicuous seams; edge details as indicated on the Architect\rquote s Drawings; __________ color. [Technical Bulletin: H-26278, CTDC 122]\cell }\pard \widctlpar\intbl { \b\fs22 \row }\pard \qc\li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 \cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\i\fs22\ul \par (*)SPECIAL REQUIREMENTS FOR HOT AND COLD APPLICATIONS. \par \cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 M.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 (*) Cold cafeteria surfaces: [1/2" (13 mm)][3/4" (19 mm)] thick CORIAN, adhesively joined with inconspicuous seams; edge details as indicated on the Architect\rquote s Drawings; ________ color. [Technical Bulletins:, CTDC 119, 124, 125] \par 1. Make cutouts to templates furnished by the cold appliance manufacturer. \par 2. Reinforce joints and cutouts as recommended by the surfacing manufacturer. \par 3. Provide insulation between CORIAN and adjacent cold pans. \par 4. Thermally isolate hot applications from cold.\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 N.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 (*) Hot cafeteria surface: [1/2" (13 mm)][3/4" (19 mm)] thick CORIAN, adhesively joined with inconspicuous seams; edge details as indicated on the Architect\rquote s Drawings; __________ color. [Technical Bulletins:, CTDC-119, 124, 125] \par 1. Provide expansion joints in countertop as detailed on the Architect\rquote s Drawings. \par 2. Make cutouts to templates furnished by the hot appliance manufacturer. \par 3. Reinforce joints and cutouts as recommended by the surfacing manufacturer. \par 4. Provide insulation between CORIAN and adjacent hot water pans and food \par warmers. \par 5. Thermally isolate hot applications from cold. \par 6. Provide venting of cabinets. (}{\b\i\fs22 Architect must design and specify.)}{\b\fs22 \cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 O.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Countertops with sinks: [1/2" (13 mm)][3/4" (19 mm)] thick countertop of CORIAN; edge details as indicated on the Architect\rquote s Drawings, complete with [undermount][seamed \ldblquote S\rdblquote mount][bevel mount][single bowl][double bowl][double bowl with molded drainboard] sink. Provide counter complete with backsplash of size shown on the Architect\rquote s Drawings. Countertop and backsplash shall be _______ color. Sink shall be _______ model and _______ color. }{\b\i\fs22 (Note: when bevel mounting the same color sink/bowl as the sheet, the "step-down" or recessed mount is recommended.)}{\b\fs22 \cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 P.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Free standing island countertops with sinks: [1/2" (13 mm)][3/4" (19 mm)] thick countertop of CORIAN; edge details as indicated on the Architect\rquote s Drawings; complete with [undermount][seamed \ldblquote S\rdblquote mount][bevel mount][single bowl][double bowl][double bowl with molded drainboard] sink. Island shall be _______ color. Sink shall be _______ model and _______ color. }{\b\i\fs22 (Note: when bevel mounting the same color sink/bowl as the sheet, the "step-down" or recessed mount is recommended.)}{\b\fs22 \cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 Q.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Lavatory tops with seamed bowls; [1/2" (13 mm)][3/4" (19 mm)] thick countertop of CORIAN, having edge details as indicated on the Architect\rquote s Drawings, complete with [seamed \ldblquote S\rdblquote undermount] [bevel mount] bowl. Provide countertops complete with backsplashes of size shown on the Architect\rquote s Drawings. }{\b\i\fs22 (Technical Bulletin H-16307)}{\b\fs22 Countertop and backsplash shall be ______ color. [specify number] bowl(s) shall be _____ model and ______ color. }{\b\i\fs22 (Note: when bevel mounting the same color sink/bowl as the sheet, the "step-down" or recessed mount is recommended.)}{ \b\fs22 \cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 R.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Lavatory tops with undermount bowls: [1/2" (13 mm)][3/4" 19 mm)] thick countertop of CORIAN; edge details as indicated on the Architect\rquote s Drawings, complete with [specify number] undermount bowl[s]. Provide cou ntertops complete with backsplashes of size shown on the Architect\rquote s Drawings. Use undermount hardware according to manufacturer's instructions. (Technical Bulletin H-16307,] Vanity top and backsplash shall be ________ color. Bowl[s] shall be }{ \b\fs22\ul _____ }{\b\fs22 model and ______ color. (}{\b\i\fs22 For ADA compliance, refer to Technical Drawings ADABOWL, ADATEMP for installation details.) }{\b\fs22 \cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \li216\widctlpar\intbl\tqr\tx9090 { \b\fs22 S.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Lavatory tops with integral bowls: molded countertop of CORIAN [19 1/2" (500 mm)][22" (560 mm)], complete with integrally molded bowl[s] of CORIAN; edge details as indicated on the Architect \rquote s Drawings. Provide with cove backsplash [and endsplashes] as shown on the Architect\rquote s Drawings. ______ model and ______ color. }{\b\i\fs22 }{\b\fs22 [Technical Bulletin CTDC-128].\cell }\pard \widctlpar\intbl {\b\fs22 \row }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx9324 \pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 T.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Window sills: [1/2" (13 mm)][3/4" (19 mm)] thick CORIAN, adhesively joined with inconspicuous seams; edge details as indicated on the Architect\rquote s Drawings; _______ color. [Technical Bulletin: CTDC-130].\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\tqr\tx9090 {\b\fs16 \par }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx9810 \pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 \column U.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Performance characteristics:\cell }\pard \widctlpar\intbl {\b\fs22 \row }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx9810 \pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 \cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 \cell }\pard \widctlpar\intbl {\b\fs22 \row }\trowd \trgaph108\trleft-108\trkeep \clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \cellx3492\clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx6612\clbrdrt\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx9810 \pard \qc\widctlpar\intbl\tqr\tx9090 {\b PROPERTY}{\b\fs22 \cell }{\b REQUIREMENT}{\b\fs22 \cell }{\b TEST PROCEDURE}{\b\fs22 \cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 \cell \cell \cell }\pard \widctlpar\intbl { \b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Tensile Strength\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 6000 psi\cell ASTM D 638\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Tensile Modulus \cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 1.5 x 10}{\b\fs22\up6 6 psi}{\b\fs22 \cell ASTM D 638\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Flexural Strength\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 7890 psi\cell ASTM D 790\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Flexural Modulus\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 1.4 x 10}{\b\fs22\up6 6 psi}{\b\fs22 \cell ASTM D 790\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Elongation\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 0.4%\cell ASTM D 638\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Strain at Break\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 0.81%\cell ASTM D 638\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Work to Break\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 2.48 in. lbs.\cell ASTM D 638\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Hardness\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 94 Rockwell "M" Scale \par 56 Barcol Impressor\cell ASTM D 785\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Thermal Expansion\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 3.02 x 10}{\b\fs22\up6 -6 }{\b\fs22 in/in/} {\field\flddirty{\*\fldinst {\b\fs22 symbol 176 \\f "Symbol"}}{\fldrslt }}{\b\fs22 C\cell ASTM D 696\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 \cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 1.80 x 10}{ \b\fs22\up6 -6 \~}{\b\fs22 in/in/}{\field\flddirty{\*\fldinst {\b\fs22 symbol 176 \\f "Symbol"}}{\fldrslt }}{\b\fs22 F\cell \cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Thermal Conductivity\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 7.0 Btu/hr/sq ft }{\field\flddirty{\*\fldinst {\b\fs22 symbol 176 \\f "Symbol"}}{\fldrslt }}{\b\fs22 F\cell DuPont Test\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Specific Heat\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 0.2935 + (0.001 % }{\field\flddirty{\*\fldinst {\b\fs22 symbol 176 \\f "Symbol"}}{\fldrslt }}{\b\fs22 C) \par pcu/lb }{\field\flddirty{\*\fldinst {\b\fs22 symbol 176 \\f "Symbol"}}{\fldrslt }}{\b\fs22 C\cell DuPont Test\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Volumetric Heat Capacity\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 0.33 Btu/lb }{\field\flddirty{\*\fldinst {\b\fs22 symbol 176 \\f "Symbol"}}{\fldrslt }}{\b\fs22 F\cell DuPont Test\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Gloss (60 Gardner)\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 5-80 (matte-polished)\cell NEMA LD 3-3.15\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Color Stability\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 No Change - 200 hrs\cell NEMA LD 3-3.10\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Wear and Cleanability\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 Passes\cell ANSI Z 124.3\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Abrasion Resistance\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 No loss of pattern \par Wt loss (1,000 cycles) - 0.2 gm \par Wear (10,000 cycles) - .008"\cell NEMA LD 3-3.10\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Boiling Water Surface Resistance\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 No Change\cell NEMA LD 3-3.05 \cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 High Temperature Resistance\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 No Change\cell NEMA LD 3-3.06\cell }\pard \widctlpar\intbl {\b\fs22 \row }\trowd \trgaph108\trleft-108\trkeep \clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \cellx3492\clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx6612\clbrdrt\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx9810 \pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Conductive Heat Resistance\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 No Change\cell NEMA LD 3-3.08\cell }\pard \widctlpar\intbl {\b\fs22 \row }\trowd \trgaph108\trleft-108\trkeep \clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb \brdrs\brdrw15 \cellx3492\clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx6612\clbrdrt\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx9810 \pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Impact Resistance \par Notched Izod \par Gardner\cell }\pard \qc\li-90\widctlpar\intbl\tqr\tx9090 {\b\fs22 \par .28 ft. lbs/in. of notch \par solid colors 9.3 ft. lbs \par particulate colors 13.3 ft. lbs\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\fs22 \par ASTM D 256 }{\fs20 (Method A) \par }{\fs22 ASTM D 3029\cell }\pard \widctlpar\intbl {\b\fs22 \row }\trowd \trgaph108\trleft-108\trkeep \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \cellx3492\clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx6612\clbrdrb \brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx9810 \pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Ball Drop \par 1/4" (6 mm) sheet \par 1/2" (13 mm) sheet \par 3/4" (19 mm) sheet\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 \par }{\field\flddirty{\*\fldinst {\b\fs22 symbol 62 \\f "Symbol"}}{\fldrslt }}{\b\fs22 36" w 1/2 lb ball, no failure \par }{\field\flddirty{\*\fldinst {\b\fs22 symbol 62 \\f "Symbol"}}{\fldrslt }}{\b\fs22 144" w 1/2 lb ball, no failure \par }{\field\flddirty{\*\fldinst {\b\fs22 symbol 62 \\f "Symbol"}}{\fldrslt }}{\b\fs22 204" w 1/2 lb ball, no failure\cell \par NEMA LD 3-3.03\cell }\pard \widctlpar\intbl {\b\fs22 \row }\trowd \trgaph108\trleft-108\trkeep \clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx3492\clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb \brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx6612\clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx9810 \pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Bowls (Point Impact)\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 No cracks or chips{\fs20 \cell }{\b\fs22 ANSI Z124.3 and 124.6\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Stain Resistance\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 Passes\cell { \b\fs22 ANSI Z124.3\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 \cell }\pard \qc\widctlpar\intbl\tqr\tx9090 Rating - 41 (modified*)\cell {\b\fs22 ANSI Z124.3(modified)\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Weatherability\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 No Change - 1000 hours\cell {\b\fs22 ASTM D 1499\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Fungi and Bacteria\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 No Attack\cell {\b\fs22 ASTM G 21, G 22\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Specific Gravity \par solid colors \par particulate colors\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 \par 1.8 \par 1.69\cell }{\b\fs20 \cell }\pard \widctlpar\intbl {\b\fs22 \row }\trowd \trgaph108\trleft-108\trkeep \clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx3492\clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx7670\clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx9810 \pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Material Weight \par solid colors \par particulate colors\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 1/4" (6 mm), 1/2" (13 mm), 3/4" (19 mm) \par 2.35 4.7 7.0 lbs/sq. ft \par 2.1 4.2 6.2 lbs/sq. ft.\cell }{\b\fs20 \cell }\pard \widctlpar\intbl {\b\fs22 \row }\trowd \trgaph108\trleft-108\trkeep \clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx3492\clbrdrt \brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx6612\clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx9810 \pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Water Absorption \par 3/4" (12 mm) sheet \par 1/4" (6 mm) sheet\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 After 24 hrs Long Term \par 0.04% 0.94% \par 0.09% 0.8%\cell ASTM D 570\cell }\pard \widctlpar\intbl {\b\fs22 \row }\trowd \trgaph108\trleft-108\trkeep \clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx3492\clbrdrt\brdrs\brdrw15 \clbrdrl \brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx7812\clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx9810 \pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Flammability \par solid colors \par Flame Spread \par Smoke Developed \par Class Rating\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 1/4"(6 mm) 1/2"(13mm) 3/4" (19mm) \par \par 25(15) 5 5 \par 25(20) 10 15 \par 1 1 1\cell \par ASTM E84\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 particulate colors \par Flame Spread \par Smoke Developed \par Class Rating\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 \par 20 15 15 \par 5 25 30 \par 1 1 1\cell }{\b\fs20 \cell }\pard \widctlpar\intbl {\b\fs22 \row }\trowd \trgaph108\trleft-108\trkeep \clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx3492\clbrdrt \brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx6612\clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx9810 \pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Oxygen Index \cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 0.357\cell ASTM D 2863\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Pittsburgh Protocol Toxicity \par (as used by NY State)\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 solid colors 99 grams \par particulate colors 67 grams\cell "LC 50" Test\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Coefficient of Friction\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 0.189 static \par 0.171 dynamic\cell DuPont Test TD-511-A\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Arc Resistance\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 190 seconds, no track \par 60 seconds, rerun, no track\cell ASTM D 495\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Dielectric Strength \par solid colors \par particulate colors\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 \par 275 volts/0.001" \par 263 volts/0.001"\cell ASTM D 149\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Dielectric Constant \par solid colors \par particulate colors\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 \par 4.96 at 100 Hz \par 4.46 at 100 Hz\cell ASTM D 150\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Dissipation Factor \par solid colors \par particulate colors\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 \par 0.0698 at 100 Hz \par 0.077 at 100 Hz\cell ASTM D150\cell }\pard \widctlpar\intbl {\b\fs22 \row }\trowd \trgaph108\trleft-108\trkeep \clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx3492\clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrr \brdrs\brdrw15 \cellx6612\clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx9810 \pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Surface Conductivity \par solid colors\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 \par 5.0 x 10}{\b\fs22\up6 16\~}{\b\fs22 Mho\cell DuPont Test TD-533-A\cell }\pard \widctlpar\intbl {\b\fs22 \row }\trowd \trgaph108\trleft-108\trkeep \clbrdrt\brdrs\brdrw15 \cellx3492\clbrdrt\brdrs\brdrw15 \cellx6612\clbrdrt\brdrs\brdrw15 \cellx9810 \pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 \par * additional stains used\tab Additional stains used. *\tab Additional stains used. \par \cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 \cell \cell }\pard \widctlpar\intbl {\b\fs22 \row }\trowd \trgaph108\trleft-108\trkeep \clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx3492\clbrdrt \brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx6612\clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx9810 \pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Volume Conductivity \par solid colors\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 \par 4.7 x 10}{\b\fs22\up6 16}{\b\fs22 Mho\cell DuPont Test TD-533-A\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Volume Resistivity \par solid colors \par particulate colors\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 \par 4.2 Ohms cm x 10}{\b\fs22\up6 -14}{\b\fs22 \par 10.0 Ohms cm x 10}{\b\fs22\up6 -14}{\b\fs22 \cell ASTM D 257\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Electrical Charge Relaxation Time \par solid colors\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 \par 560 seconds\cell PTMS 101B, \par MIL B-81705\cell }\pard \widctlpar\intbl {\b\fs22 \row }\trowd \trgaph108\trleft-108\trkeep \clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx3492\clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb \brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx6612\clbrdrt\brdrs\brdrw15 \clbrdrl\brdrs\brdrw15 \clbrdrb\brdrs\brdrw15 \clbrdrr\brdrs\brdrw15 \cellx9810 \pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Heat of Combustion\cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\fs22 2.20 cal/gm\cell Oxygen bomb \par (calorimeter method)\cell }\pard \widctlpar\intbl {\b\fs22 \row }\pard \widctlpar\tqr\tx9090 {\b\fs22 \par }\pard \widctlpar\tx360\tqr\tx9090 {\b\fs22 \par }\trowd \trgaph108\trleft-108\trkeep \cellx9252 \pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 \column }{\b 2.02 ACCESSORY PRODUCTS \par \cell }\pard \widctlpar\intbl {\b \row }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx9324 \pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 A.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Joint adhesive: Manufacturer's standard two-part adhesive kit to create inconspicuous, non-porous joints, with a chemical bond. (Technical Bulletin: CTDC 102)\cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 \cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\b\i\fs22 (}{\i\fs20 RETAIN BELOW FOR TUB/SHOWER SYSTEMS)}{\b\i\fs22 \cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 B.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Panel Adhesive: Manufacturer's standard neoprene-based panel adhesive meeting ANSI A 136.1-1967 UL\'ae listed. (Technical Bulletin: CTDC 102)\cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 C.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Sealant: Manufacturer's standard mildew-resistant, FDA/UL\'ae recognized silicone sealant in color matching or clear formulations. (Technical Bulletin: 102, 127)\cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 \cell }\pard \qc\widctlpar\intbl\tqr\tx9090 {\i\fs20 (RETAIN BELOW FOR UNDERMOUNT SINKS AND BOWLS)\cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 D.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Sink/Bowl mounting hardware: Manufacturer's approved bowl clips, brass inserts and fasteners for attachment of undermount sinks/bowls.\cell }\pard \widctlpar\intbl {\b \row }\trowd \trgaph108\trleft-108\trkeep \cellx9252 \pard \li180\widctlpar\intbl\tqr\tx9090 {\b \par 2.03 FABRICATION \par \cell }\pard \widctlpar\intbl {\b \row }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx9324 \pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 A.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 [Fabrications to be performed by a Certified CORIAN fabricator/installer.]\cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 B.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Fabricate components in shop to greatest extent practical to sizes and shapes indicated, in accordance with approved shop drawings and DuPont requirements. (Technical Bulletin: CTDC-117)\cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 C.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Form joints between components using manufacturer's standard joint adhesive. Joints shall be inconspicuous in appearance and without voids. Attach 2" (50 mm) wide reinforcing strip of CORIAN under each joint. [Technical Bulletins: CTDC-124, 129, 134] \cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 D.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Provide holes and cutouts for plumbing and bath accessories as indicated on the drawings.\cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 E.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Rout and finish component edges to a smooth, uniform finish. Rout all cutouts, then sand all edges smooth. Repair or reject defective or inaccurate work.\cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 F.\cell }\pard \ri-54\widctlpar\intbl\tqr\tx9090 {\b\fs22 Finish: All surfaces shall have uniform finish. [Technical Bulletins:CTDC100, 123, 132] \par 1. [Matte ,with a gloss rating of 5 - 20.] }{\b\i\fs22 (This the standard finish and is the lowest \par maintenance finish.) \par }{\b\fs22 2. [Semigloss, with a gloss rating of 25-50] }{\b\i\fs22 (Adds an upcharge. Select semigloss to bring out the depth of colors in the darker Sierra and Jewel tones. It requires more maintenance.) \par }{\b\fs22 3. [ Polished, with a gloss rating of 55 - 80.] }{\b\i\fs22 (A high gloss finish, ideal for applications that require maximum smoothness and reflectance. Recommended for light duty only. Maintenance will be increased.)}{\b\fs22 \cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 G.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\i\fs22 (Optional)}{\b\fs22 Thermoforming: Comply with forming data from manufacturer. (Technical Bulletin CTDC-110] \par 1. Construct matching molds of plywood to form component shape. \par 2. Form pieces to shape prior to seaming and joining. \par 3. Cut pieces larger than finished dimensions. Sand edges. Remove all nicks and \par scratches. \par 4. Heat entire component uniformly between 275-325}{\field\flddirty{\*\fldinst {\b\fs22 symbol 176 \\f "Symbol"}}{\fldrslt }}{\b\fs22 F during forming. \par 5. Prevent blistering, whitening and cracking of CORIAN during forming.\cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 H.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\i\fs22 (Optional)}{\b\fs22 Cove backsplashes: Fabricate 1/2" (13 mm) radius cove at intersection of counters and backsplashes. Form backsplashes using [1/2" (13 mm)][3/4" (19 mm)] CORIAN. Fabricate in shop or field. [Technical Bulletin: CTDC-112]\cell }\pard \widctlpar\intbl {\b \row }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx9324 \pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 I.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\i\fs22 (Optional)}{\b\fs22 Colored inlays: Fabricate using manufacturer\rquote s approved method. \par (Technical Bulletin CTDC-103) \par 1. Rout 1/8\rdblquote max deep groove for inlay to pattern indicated on Architect\rquote s Drawings. \par 2. Fill groove using methods approved by manufacture, avoiding air bubbles or \par voids. Overfill inlay area. \par 3. Allow area to fully cure. Do not overheat inlay while sanding. Finish and \par touch up to uniform appearance.\cell }\pard \widctlpar\intbl {\b \row }\pard \widctlpar\tx360\tqr\tx9090 {\b\fs22 \par }{\b\i\fs22 [Refer to DuPont CORIAN Fabrication and Installation manual E-88639. Technical information and a listing of the registered DuPont CORIAN fabricator/installers can be provided by the local DuPont CORIAN distributor.] \par }{\b\fs22 \par }{\b III. EXECUTION \par }\pard \qc\widctlpar\tx360\tqr\tx9090 {\b\i\fs22 (}{\i\fs22 USE DETAILS BELOW FOR LARGE OR INTRICATE PROJECTS}{\b\i\fs22 .) \par }{\i\fs20 [NOTE: MANUFACTURER RECOMMENDS A CERTIFIED FABRICATOR BE USED FOR FABRICATION AND/OR INSTALLATION, WHICH WILL ENSURE WARRANTY COVERAGE AND ASSURE A QUALITY INSTALLATION.] \par }{\b\fs22 \par }\trowd \trgaph108\trleft-108\trkeep \cellx9252 \pard \widctlpar\intbl\tqr\tx9090 {\b 3.01 JOB MOCK-UP\cell }\pard \widctlpar\intbl {\b \row }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx9324 \pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 A. \cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Prior to final approval of shop drawings, erect one full size mock-up of each component at project site for architect review.\cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 B.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Should mock-up not be approved, rework or remake until approval is secured. Remove rejected units from project site.\cell }\pard \widctlpar\intbl {\b \row }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx9324 \pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 C.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Approved mock-ups shall remain as part of finished work.\cell }\pard \widctlpar\intbl {\b \row }\pard \widctlpar\tx360\tqr\tx9090 { \b\fs22 \par }\trowd \trgaph108\trleft-108\trkeep \cellx9252 \pard \widctlpar\intbl\tqr\tx9090 {\b 3.02 INSTALLATION\cell }\pard \widctlpar\intbl {\b \row }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx9324 \pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 A. \cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Install components plumb and level, in accordance with approved shop drawings and product installation details.\cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 B. \cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Form field joints using manufacturer's recommended adhesive, with joints inconspicuous in finished work. Keep components and hands clean when making joints.\cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 C.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Adhere undermount/submount/bevel mount sinks/bowls to countertops using manufacturer's recommended adhesive and mounting hardware. [Technical Bulletin H-16307] \cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 D.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Adhere topmount sinks/bowls to countertops using manufacturer recommended adhesives and color-matched silicone sealant.\cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 E.\cell }\pard \widctlpar\intbl\tqr\tx9090 { \b\fs22 Provide backsplashes and endsplashes as indicated on the drawings. Adhere to countertops using manufacturer's standard color-matched silicone sealant.\cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 F. \cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Keep components and hands clean during installation. Remove adhesives, sealants and other stains. Components shall be clean on Date of Substantial Completion..\cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 G.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Make plumbing connections to sinks in accordance with Division 15. Mechanical.\cell }\pard \widctlpar\intbl {\b \row }\pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 H.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Protect surfaces from damage until Date of Substantial Completion. Repair or replace damaged work that cannot be repaired to architect's satisfaction and invoice for the cost of repairs. Architect to pre-approve cost estimate before repairs are made. \cell }\pard \widctlpar\intbl {\b \row }\trowd \trgaph108\trleft-108\trkeep \cellx684\cellx9324 \pard \li216\widctlpar\intbl\tqr\tx9090 {\b\fs22 I.\cell }\pard \widctlpar\intbl\tqr\tx9090 {\b\fs22 Fabricator/Installer is to provide the CORIAN [Commercial][Residential] Care and Maintenance video, review maintenance procedures and the DuPont warranty with the head of maintenance upon completion of project.\cell }\pard \widctlpar\intbl {\b \row }\pard \widctlpar\tx360\tqr\tx9090 \par }