{\rtf1\ansi\ansicpg1252\uc1 \deff0\deflang1033\deflangfe1033{\fonttbl{\f0\froman\fcharset0\fprq2{\*\panose 02020603050405020304}Times New Roman;}}{\colortbl;\red0\green0\blue0;\red0\green0\blue255;\red0\green255\blue255;\red0\green255\blue0; \red255\green0\blue255;\red255\green0\blue0;\red255\green255\blue0;\red255\green255\blue255;\red0\green0\blue128;\red0\green128\blue128;\red0\green128\blue0;\red128\green0\blue128;\red128\green0\blue0;\red128\green128\blue0;\red128\green128\blue128; \red192\green192\blue192;}{\stylesheet{\nowidctlpar\widctlpar\adjustright \fs20\cgrid \snext0 Normal;}{\s1\keepn\nowidctlpar\widctlpar\adjustright \b\i\fs20\cgrid \sbasedon0 \snext0 heading 1;}{\s2\keepn\nowidctlpar\widctlpar\adjustright \b\fs20\cgrid \sbasedon0 \snext0 heading 2;}{\s3\li720\keepn\nowidctlpar\widctlpar\adjustright \b\i\fs20\cgrid \sbasedon0 \snext0 heading 3;}{\s4\li720\keepn\nowidctlpar\widctlpar\adjustright \b\fs20\cgrid \sbasedon0 \snext0 heading 4;}{\*\cs10 \additive Default Paragraph Font;}{\s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid \sbasedon0 \snext15 Body Text;}{\s16\li5040\nowidctlpar\widctlpar\adjustright \b\fs28\cgrid \sbasedon0 \snext16 Body Text 2;}{\s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid \sbasedon0 \snext17 Body Text Indent 2;}}{\info{\author Diana Chiodi}{\operator VISCOMM}{\creatim\yr1999\mo5\dy20\hr9}{\revtim\yr1999\mo5\dy20\hr9}{\printim\yr1998\mo9\dy29\hr8\min59}{\version2}{\edmins1}{\nofpages3}{\nofwords1005} {\nofchars5734}{\*\company }{\nofcharsws7041}{\vern71}}\widowctrl\ftnbj\aenddoc\formshade\viewkind1\viewscale110\pgbrdrhead\pgbrdrfoot \fet0\sectd \linex0\endnhere\sectdefaultcl {\*\pnseclvl1\pnucrm\pnstart1\pnindent720\pnhang{\pntxta .}}{\*\pnseclvl2 \pnucltr\pnstart1\pnindent720\pnhang{\pntxta .}}{\*\pnseclvl3\pndec\pnstart1\pnindent720\pnhang{\pntxta .}}{\*\pnseclvl4\pnlcltr\pnstart1\pnindent720\pnhang{\pntxta )}}{\*\pnseclvl5\pndec\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl6 \pnlcltr\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl7\pnlcrm\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl8\pnlcltr\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl9\pnlcrm\pnstart1\pnindent720\pnhang {\pntxtb (}{\pntxta )}}\pard\plain \fi720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {\tab \tab \tab \tab \tab \tab }{\b INSTALLATION: \par }\pard \li5040\nowidctlpar\widctlpar\adjustright {\b Ceramic, Mosaic, Quarry, Paver, Slate, Marble and Granite \par \par }\pard \nowidctlpar\widctlpar\adjustright {\b\fs32 \par \par }\pard\plain \s16\nowidctlpar\widctlpar\adjustright \b\fs28\cgrid {\b0\fs32 SPECIFICATION}{\fs32 \tab }{\tab \tab \tab }{\fs44 KERAFONIC}{\fs20 \par \tab \tab \tab \tab \tab \tab \tab }{\b0\fs20 Sound Deadening Mortar Underlayment \par }{\b0 \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {* \par }{\b\i DESCRIPTION:}{\i A t wo-component sound control mortar underlayment designed for applications over interior floors of concrete or exterior grade plywood (interior dry areas only) prior to setting ceramic tile. KERAFONIC reduces impact noise and sound transmission between flo ors in multi-story construction, making it ideal for condominiums and apartment buildings. \par \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i Specify for applications requiring reduction of impact noise or sound transmission between floors where ceramic tile will be installed. \par }\pard \nowidctlpar\widctlpar\adjustright {\i \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i Specify for applications in apartments, condominiums and office buildings, or where foot traffic is anticipated (see data sheet regarding LIMITATIONS). \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i Specify for interior use only. \par }\pard \nowidctlpar\widctlpar\adjustright {\i \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\b\i DO NOT}{\i specify for exterior use. \par }\pard \nowidctlpar\widctlpar\adjustright {\i \par }\pard\plain \s3\li720\keepn\nowidctlpar\widctlpar\outlinelevel2\adjustright \b\i\fs20\cgrid {DO NOT }{\b0 specify as a dry-set mortar.}{ \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\b\i DO NOT }{\i specify over particleboard, chipboard, masonite, Lauan, gypsum floor patching compounds, metal or similar dimensionally unstable materials. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i When specifying KERAFONIC in the Tile Selection selected \endash ceramic, mosaic, quarry, paver, slate, marble or granite \endash please add appropriate articles or paragraphs under the applicable }{ \b\i PART}{\i as indicated.}{ \par }\pard \nowidctlpar\widctlpar\adjustright { \par * \par }\pard\plain \s2\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {PART 1 GENERAL \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }\pard\plain \s2\li720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {REFERENCES \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {ASTM E90 - Method for Laboratory Measurement of Airborne-Sound Transmission Loss of Building Partitions \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {ASTM E413 \endash Standard Classification for Determining Sound Transmission Class (STC) \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {ASTM E492 \endash Method of Laboratory Measurement of Impact Sound Transmission through Floor/Ceiling Assemblies using the Tapping Machine \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {ASTM E989 \endash Classification for Determining Impact Insulation Class (IIC) \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {ISO 140 \endash Acoustics \endash Measurements of Sound Installaion in Buildings and at Building Elements: Part IV \endash Laboratory Measurement of Impact Sound Insulation of Floors, and Part VII \endash Field Measurements of Impact Sound Insulation of Floors. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Tile Council of America, Inc. (TCA) \endash Handbook for Ceramic Tile Installation \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par }\pard\plain \s2\li720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {SUBMITTALS \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Product Data: Submit manufacturer\rquote s technical information and installation instructions for materials required. \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par }\pard\plain \s4\li720\keepn\nowidctlpar\widctlpar\outlinelevel3\adjustright \b\fs20\cgrid {QUALITY ASSURANCE \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Provide tile, grout and setting materials from one source. Underlayment, additives, dry-set mortars, installation materials and grouts shall be from the same manufacturer. \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par }\pard\plain \s4\li720\keepn\nowidctlpar\widctlpar\outlinelevel3\adjustright \b\fs20\cgrid {DELIVERY, STORAGE AND HANDLING \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {Deliver and store packaged materi als in original containers with seals unbroken and labels intact until time of use. Prevent damage or contamination to materials by water, freezing, foreign matter or other causes. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Take necessary protective measures against freezing at all times. Once liquid component has frozen, it cannot be used. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Limited product shelf life: 3 months (at 70 degrees F). \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Deliver and store materials on site at least 24 hours before work begins. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Provide heated and dry storage facilities on site. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard\plain \s4\li720\keepn\nowidctlpar\widctlpar\outlinelevel3\adjustright \b\fs20\cgrid {PROJECT CONDITIONS \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {Maintain environmental conditions and protect work during and after installation to comply with referenced standards and manufacturer\rquote s printed recommendations. \par }\pard\plain \li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par Vent temporary heaters to exterior to prevent damage to tilework from carbon dioxide build-up. \par \par Maintain temperatures at no less than 50 degrees F (10 degrees C) in tiled areas during installation and for 7 days after completion, unless higher temperatures are required by referenced installation standards or manufacturer\rquote s written instructions. \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par PART 2 PRODUCTS \par }{ \par }\pard\plain \s4\li720\keepn\nowidctlpar\widctlpar\outlinelevel3\adjustright \b\fs20\cgrid {MATERIALS \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard \li720\nowidctlpar\widctlpar\adjustright { SOUND CONTROL UNDERLAYMENT: KERAFONIC underlayment system consisting of two-components, as manufactured by MAPEI CORPORATION, Sound Transmission Class (STC) ASTM E90 and ASTM E413, and Impact Insulation Class (IIC) ASTM E492 and ASTM E989.}{\i \par }\pard \nowidctlpar\widctlpar\adjustright {\i \par *}{\b \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {When specifying KERAFONIC in performance specification, Call MAPEI CORPORATION\rquote s Technical Service Department toll-free number for assistance with product characteristics. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\i \par When specifying MORTAR MATERIALS for setting tile over KERAFONIC, specify only KERALASTIC universal setting systems (ANSI A118.4) (See specification sheet). \par \par When specifying GROUT MATERIALS, specify ULTRA/COLOR sanded polymer-modified cementitio us grout or KER 200 sanded polymer-modified Portland cement grout (ANSI A118.6) (see specification sheets). Grout tile according to grout instructions and ANSI A108.10 specifications. \par }{* \par \par }\pard\plain \s2\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {MIXES \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Proportion and mix factory-prepared mortar with acrylic latex additive in accordance with manufacturer\rquote s printed instructions. \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par PART 3 EXECUTION \par \par }{* \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {Specifications for surface conditions are listed in the beginning of the specification of MAPEI\rquote s Architectural Binder. These specifications should be called out with the related work sections. Delete non-applicable conditions. (Refer to ANSI EXPLANATION AND NOTES section: AN-3 RELATED WORK SPECIFIED IN OTHER SECTIONS.) \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {* \par \par }\pard\plain \s2\fi720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {EXAMINATION \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Examine surfaces to receive underlayment and conditions under which underlayment will be installed. Do not proceed until surfaces and conditions comply with manufacturer\rquote s requirements. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard\plain \s2\fi720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {INSTALLATION \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {Install sound control underlayment in accordance with manufacturer\rquote s printed instructions. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par * \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {No TCA installation method for sound control underlayments exists at this time. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\i * \par }{ \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {Install expansion and control joints in area with TCA method EJ171. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard\plain \s2\fi720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {PROTECTION \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Protect KERAFONIC underlayment for at least 48 hours or until ceramic tile is installed. Cooler temperatures or thicker cross-sections may extend the setting time of the underlayment. \par \par Protect finished work from general traffic for at least 72 hours after installation. Plywood or stepping boards may be used after 24 hours when occasional stepping on the floor is unavoidable or when surface has hardened enough to prevent damage. \par }\pard \nowidctlpar\widctlpar\adjustright { \par * \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid { When dealing with cement-based products, it should be noted that temperature and humidity during and after installation of tile affect final curing time, i.e., low temperatures (60 degrees and under) and high humi dity (70% and above) will delay final cure time. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {* \par \par For further information and assistance, contact: \par \par }\pard \sa120\nowidctlpar\widctlpar\adjustright {\tab \tab \tab \tab MAPEI CORPORATION \par \tab \tab \tab \tab 1501 WALL STREET \par \tab \tab \tab \tab GARLAND, TEXAS 75041-4046 \par \tab \tab \tab \tab 1-800-992-6273 \par }}