{\rtf1\ansi\ansicpg1252\uc1 \deff0\deflang1033\deflangfe1033{\fonttbl{\f0\froman\fcharset0\fprq2{\*\panose 02020603050405020304}Times New Roman;}}{\colortbl;\red0\green0\blue0;\red0\green0\blue255;\red0\green255\blue255;\red0\green255\blue0; \red255\green0\blue255;\red255\green0\blue0;\red255\green255\blue0;\red255\green255\blue255;\red0\green0\blue128;\red0\green128\blue128;\red0\green128\blue0;\red128\green0\blue128;\red128\green0\blue0;\red128\green128\blue0;\red128\green128\blue128; \red192\green192\blue192;}{\stylesheet{\nowidctlpar\widctlpar\adjustright \fs20\cgrid \snext0 Normal;}{\s1\keepn\nowidctlpar\widctlpar\adjustright \b\i\fs20\cgrid \sbasedon0 \snext0 heading 1;}{\s2\keepn\nowidctlpar\widctlpar\adjustright \b\fs20\cgrid \sbasedon0 \snext0 heading 2;}{\*\cs10 \additive Default Paragraph Font;}{\s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid \sbasedon0 \snext15 Body Text;}{\s16\li5040\nowidctlpar\widctlpar\adjustright \b\fs28\cgrid \sbasedon0 \snext16 Body Text 2;}{ \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid \sbasedon0 \snext17 Body Text Indent 2;}}{\info{\author Diana Chiodi}{\operator VISCOMM}{\creatim\yr1999\mo5\dy20\hr8\min55}{\revtim\yr1999\mo5\dy20\hr8\min55}{\printim\yr1998\mo10\dy1\hr15\min1} {\version2}{\edmins1}{\nofpages4}{\nofwords1052}{\nofchars5998}{\*\company }{\nofcharsws7365}{\vern71}}\widowctrl\ftnbj\aenddoc\formshade\viewkind1\viewscale114\viewzk2\pgbrdrhead\pgbrdrfoot \fet0\sectd \linex0\endnhere\sectdefaultcl {\*\pnseclvl1 \pnucrm\pnstart1\pnindent720\pnhang{\pntxta .}}{\*\pnseclvl2\pnucltr\pnstart1\pnindent720\pnhang{\pntxta .}}{\*\pnseclvl3\pndec\pnstart1\pnindent720\pnhang{\pntxta .}}{\*\pnseclvl4\pnlcltr\pnstart1\pnindent720\pnhang{\pntxta )}}{\*\pnseclvl5 \pndec\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl6\pnlcltr\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl7\pnlcrm\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl8\pnlcltr\pnstart1\pnindent720\pnhang {\pntxtb (}{\pntxta )}}{\*\pnseclvl9\pnlcrm\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}\pard\plain \li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {\tab \tab \tab \tab \tab \tab }{\b INSTALLATION: \par }\pard \li5040\nowidctlpar\widctlpar\adjustright {\b Ceramic, Mosaic, Quarry, Paver, Slate, Marble and Granite \par }\pard \nowidctlpar\widctlpar\adjustright {\b\fs32 \par \par }\pard\plain \s16\nowidctlpar\widctlpar\adjustright \b\fs28\cgrid {\b0\fs32 SPECIFICATION}{\fs32 \tab }{\tab \tab \tab }{\fs44 KERASET}{\fs20 \par \tab \tab \tab \tab \tab \tab \tab Floor and Wall-Dry-Set Mortar \par }\pard \s16\li5040\nowidctlpar\widctlpar\adjustright {\fs20 \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {* \par }{\b\i DESCRIPTION:}{\i A specially formulated dry-set mortar for ceramic floor and wall tile installations (see technical data sheet for additional information.) \par }{\b\i \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i Specify for interior and exterior floor and wall installations of vitreous, semi-citreous, and non-vitreous ceramic tile, ceramic mosaic tile, quarry, paver, and natural stone tile. \par }\pard \nowidctlpar\widctlpar\adjustright {\i \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i For installations in freeze/thaw environments or with special substrates, specify KERASET with KERAPLY (see KERAPLY and other polymer additive data sheets for details.) \par \par For installations over exterior grade plywood (interior residential floor and countertop in dry areas only) specify KERASET with KERAPLY. \par \par }{\b\i DO NOT}{\i specify for setting Rosso Levanto and Negro Marquina marble, green marble and granite or their agglomerates. Specify PLANICRETE W or KERAPOXY. When specifying light colored and translucent marble and their agglomerates, specify White GRANI/RAPID or White KERAQUICK M (see data sheets for details). \par \par }{\b\i DO NOT }{\i specify over presswood, particle board, chipboard, masonite, Lauan, gypsum floor patching compounds or similar dimensionally unstable substrates. \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i When specifying KERASET in the Tile Selection selected \endash ceramic, mosaic, quarry, paver, slate, marble or granite \endash add appropriate articles or paragraphs under the applicable }{\b\i PART} {\i as indicated.}{ \par }\pard \nowidctlpar\widctlpar\adjustright {* \par }\pard\plain \s2\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {PART 1 GENERAL \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par \tab REFERENCES \par \tab \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {ANSI A108.5 \endash Installation of Ceramic Tile with Dry-Set Portland Cement Mortar or Latex-Portland Cement Mortar \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \tab \par }\pard \fi720\nowidctlpar\widctlpar\adjustright {ANSI A118.1 \endash Specifications for Dry-Set Portland Cement Mortar \par }{\b \par }{ANSI A137.1 \endash Specification for Ceramic Tile \par \par Tile Council of America (TCA) \endash Handbook for Ceramic Tile Installation}{\b \par \par SUBMITTALS \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Product Data: Submit manufacturer\rquote s technical information and installation instructions for materials required. \par }{\b \par }\pard \nowidctlpar\widctlpar\adjustright {\b \tab QUALITY ASSURANCE \par }{\tab \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {Provide tile, grout and setting materials from one source. Additives, dry-set mortars, installation materials and grouts shall be from the same manufacturer. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par \tab DELIVERY, STORAGE AND HANDLING \par }{\tab \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Deliver and store packaged materials in original containers with seals unbroken and labels intact until time of use. Prevent damage or contamination to materials by water, freezing, foreign matter or other causes. \par \par Deliver and store materials on site at least 24 hours before work begins. \par \par Provide heated and dry storage facilities on site. \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par \tab PROJECT CONDITIONS \par \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Maintain environmental conditions and protect work during and after installation to comply with referenced standards and manufacturer\rquote s printed recommendations. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \fi720\nowidctlpar\widctlpar\adjustright {Vent temporary heaters to exterior to prevent damage to tilework from carbon dioxide build-up. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Maintain temperature at not less than 50 degrees F (10 degrees C) in tiled areas during installation and for 7 days after completion, unless higher temperatures ar e required by referenced installation standards or manufacturer\rquote s written instructions. \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par \par PART 2 PRODUCTS \par }{ \par }{\b \tab MORTAR MATERIALS \par }{\i \par }\pard \li720\nowidctlpar\widctlpar\adjustright {DRY-SET MORTAR: KERASET floor and wall dry-set mortar, as manufactured by MAPEI CORPORATION, ANSI A118.1}{\i \tab \tab \par \par }\pard \nowidctlpar\widctlpar\adjustright {\i *}{\b \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {When specifying KERASET in performance specification, Call MAPEI CORPORATION\rquote s Technical Service Department toll-free number for assistance with product characteristics. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\i \par \par Specify KERAPLY or PLANICRETE 50 latex additives with KERASET when specifying LATEX-PORTLAND CEMENT MORTAR, ANSI A118.4 (see respective specification sheets). \par \par When specifying GROUT MATERIALS, refer to respective suggested grout specification \endash ULTRA/COLOR sanded polymer- modified cementitious grout or KER 200 polymer-modified Portland cement tile grout or KER 800 unsanded polymer-modified Portland cement tile grout (ANSI A118.6), or KERAPOXY 100% Solids Epoxy Grout (ANSI A118.3). ). Grout tiles according to grout instruc tions and ANSI A108.10 or A108.6 specifications. \par \par }{* \par \par }\pard\plain \s2\fi720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {MIXES \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \tab \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Proportion and mix factory-prepared mortar in accordance with manufacturer\rquote s printed instructions. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }{\b \par PART 3 EXECUTION \par \par }{* \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {Specifications for surface conditions are listed in the beginning of the specification of MAPEI\rquote s Architectural Binder. These specifications should be called ou t with the related work sections. Delete non-applicable conditions. (Refer to ANSI EXPLANATION AND NOTES section: AN-3 RELATED WORK SPECIFIED IN OTHER SECTIONS.) \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {* \par \par }\pard\plain \s2\fi720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {EXAMINATION \par }\pard\plain \li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par Examine surfaces to receive tilework and conditions under which tile will be installed. Do not proceed with tilework until surfaces and conditions comply with requirements indicated in reference tile installation standards and manufacturer\rquote s pri nted instructions. \par }\pard \nowidctlpar\widctlpar\adjustright { \par \par }\pard\plain \s2\fi720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {INSTALLATION \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par \tab Install tile in accordance with manufacturer\rquote s printed instructions and ANSI A108.5 \par \par \par \par * \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {Select appropriate TCA method to be used and delete non-applicable methods (select from latest edition of TCA Handbook). \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\i *}{ \par \par \tab [Floor Tile: Install in accordance with TCA method \par \tab [F101], [F102], [F103], [F111], [F112], [F113], [F114], \par \tab [F115], [F122], [F141], [F144], [TR712], [RF912].] \par \par \tab [Wall Tile: Install in accordance with TCA method \par \tab [W201], [W202], [W203], [W221], [W222], [W231], [W241], \par \tab [W243], [W244], [B412], [B413], [B414], [B415], [TR713].] \par \par \tab Install expansion and control joints in accordance with TCA method EJ171. \par \par \tab Grout joints shall be clean and free from standing water, dust and foreign substances. \par \par Tile surfaces shall be clean and dry. \par \par \par }\pard\plain \s2\fi720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {PROTECTION \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par * \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {Select appropriate statements for installation \endash floor, wall or both. Delete non-applicable statements. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {* \par }\pard \li720\nowidctlpar\widctlpar\adjustright {[Protect floors from general traffic for at least 24 hours after installation.] \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {[Protect walls from impact, vibration and heavy hammering on adjacent and opposite walls for at least 2 days after installation.] \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \fi720\nowidctlpar\widctlpar\adjustright {Protect from freezing and total water immersion for at least 21 days after installation. \par }\pard \nowidctlpar\widctlpar\adjustright { \par \par * \par When dealing with cement-based products, it should be noted that temperature and humidity during and after installation of tile affect final curing time, i.e., low temperatures (60 degrees and under) and high humidity (70% and above) will delay final cure time. \par * \par \par For further information and assistance, contact: \par \par \par }\pard \sa120\nowidctlpar\widctlpar\adjustright {\tab \tab \tab \tab MAPEI CORPORATION \par \tab \tab \tab \tab 1501 WALL STREET \par \tab \tab \tab \tab GARLAND, TEXAS 75041 \endash 4046 \par \tab \tab \tab \tab 1-800-992-6273 \par }}