{\rtf1\ansi\ansicpg1252\uc1 \deff0\deflang1033\deflangfe1033{\fonttbl{\f0\froman\fcharset0\fprq2{\*\panose 02020603050405020304}Times New Roman;}}{\colortbl;\red0\green0\blue0;\red0\green0\blue255;\red0\green255\blue255;\red0\green255\blue0; \red255\green0\blue255;\red255\green0\blue0;\red255\green255\blue0;\red255\green255\blue255;\red0\green0\blue128;\red0\green128\blue128;\red0\green128\blue0;\red128\green0\blue128;\red128\green0\blue0;\red128\green128\blue0;\red128\green128\blue128; \red192\green192\blue192;}{\stylesheet{\nowidctlpar\widctlpar\adjustright \fs20\cgrid \snext0 Normal;}{\s1\keepn\nowidctlpar\widctlpar\adjustright \b\i\fs20\cgrid \sbasedon0 \snext0 heading 1;}{\s2\keepn\nowidctlpar\widctlpar\adjustright \b\fs20\cgrid \sbasedon0 \snext0 heading 2;}{\s3\li720\keepn\nowidctlpar\widctlpar\adjustright \b\i\fs20\cgrid \sbasedon0 \snext0 heading 3;}{\*\cs10 \additive Default Paragraph Font;}{\s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid \sbasedon0 \snext15 Body Text;} {\s16\li5040\nowidctlpar\widctlpar\adjustright \b\fs28\cgrid \sbasedon0 \snext16 Body Text 2;}{\s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid \sbasedon0 \snext17 Body Text Indent 2;}}{\info{\author Diana Chiodi}{\operator VISCOMM} {\creatim\yr1999\mo5\dy20\hr9\min8}{\revtim\yr1999\mo5\dy20\hr9\min8}{\printim\yr1998\mo9\dy30\hr9\min48}{\version2}{\edmins1}{\nofpages4}{\nofwords1132}{\nofchars6456}{\*\company }{\nofcharsws7928}{\vern71}} \widowctrl\ftnbj\aenddoc\formshade\viewkind1\viewscale114\viewzk2\pgbrdrhead\pgbrdrfoot \fet0\sectd \linex0\endnhere\sectdefaultcl {\*\pnseclvl1\pnucrm\pnstart1\pnindent720\pnhang{\pntxta .}}{\*\pnseclvl2\pnucltr\pnstart1\pnindent720\pnhang{\pntxta .}} {\*\pnseclvl3\pndec\pnstart1\pnindent720\pnhang{\pntxta .}}{\*\pnseclvl4\pnlcltr\pnstart1\pnindent720\pnhang{\pntxta )}}{\*\pnseclvl5\pndec\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl6\pnlcltr\pnstart1\pnindent720\pnhang{\pntxtb (} {\pntxta )}}{\*\pnseclvl7\pnlcrm\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl8\pnlcltr\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl9\pnlcrm\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}\pard\plain \li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {\tab \tab \tab \tab \tab \tab }{\b INSTALLATION: \par \tab \tab \tab \tab \tab \tab Ceramic, Mosaic, Quarry, \par \tab \tab \tab \tab \tab \tab Paver, Marble and Granite \par }\pard \nowidctlpar\widctlpar\adjustright {\b\fs32 \par \par }\pard\plain \s16\nowidctlpar\widctlpar\adjustright \b\fs28\cgrid {\b0\fs32 SPECIFICATION}{\fs32 \tab }{\tab \tab \tab }{\fs44 PLANICRETE W \par }\pard \s16\li5040\nowidctlpar\widctlpar\adjustright {\fs20 Heavy- Duty Flexible Two-Component Specialty Adhesion \par \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {* \par }{\b\i DESCRIPTION:}{\i A white, high bond strength, highly flexible, trowable two-component specialty adhesive for interior and exterior installations. PLANICRETE W is designed for setting ceramic tile and stone (except white or translucent marble) over most subs trates, including steel. It is ideally suited for setting Rosso Levanto and Negro Marquina marble or green marble or green granite or their agglomerates. \par }{\b\i \par }{\tab }{\i Specify for setting in kitchens and wet areas in hotels, hospitals, bathrooms and care units. \par \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i Specify for specialized heavy-duty interior and exterior applications. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i Specify for use as a high strength setting compounds when installing ceramic tile over steel decks (shipbuilding) elevator floors and walls, exterior grade plywood (interior floors and cou ntertops dry areas only), gypsum wallboard, concrete, cementitious backer unit and in areas subject to excessive vibration an movement. \par }\pard \nowidctlpar\widctlpar\adjustright {\i \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i Specify for setting tile on prefabricated bath units on walls and floors. \par \par Specify for exterior applications in setting Rosso Levanto, and Negro Marquina marble or green marble or green granite and their agglomerates. \par \par }{\b\i DO NOT }{\i specify for the installation of light colored marble. When installing light colored marble and other translucent marble and their agglomerates, specify white GRANI/RAPID or White KERAQUICK M.. \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par }\pard\plain \s3\li720\keepn\nowidctlpar\widctlpar\outlinelevel2\adjustright \b\i\fs20\cgrid {DO NOT }{\b0 specify over particle board, masonite, chipboard, Lauan, gypsum floor patching compounds, metal or similar dimensionally unstable substrates. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b\i \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i When specifying PLANICRETE W in the Tile Selection selected \endash ceramic, mosaic, quarry, paver, slate, marble or granite \endash add appropriate articles or paragraphs under the applicable }{\b\i PART}{\i as indicated.}{ \par }\pard \nowidctlpar\widctlpar\adjustright {* \par }\pard\plain \s2\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {PART 1 GENERAL \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par \tab REFERENCES \par }{* \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {There are no industry standards covering Polyurethane adhesives. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {* \par \par ANSI A173.1 \endash Specifications for Ceramic Tile \par \par Tile Council of America (TCA) \endash Handbook for Ceramic Tile Installation \par \par }{\i \par }{\b \tab \par }\pard \fi720\nowidctlpar\widctlpar\adjustright {\b \par SUBMITTALS \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Product Data: Submit manufacturer\rquote s technical information and installation instructions for materials required. \par }{\b \par }\pard \nowidctlpar\widctlpar\adjustright {\b \tab QUALITY ASSURANCE \par }{\tab \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {Provide tile, grout and setting materials from one source. Additives, dry-set mortars, installation materials and grouts shall be from the same manufacturer. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \tab \par \tab DELIVERY, STORAGE AND HANDLING \par }{\tab \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Deliver and store packaged materials in original containers wit h seals unbroken and labels intact until time of use. Prevent damage or contamination to materials by water, freezing, foreign matter or other causes. \par \par Deliver and store materials on site at least 24 hours before work begins. \par \par Provide heated and dry storage facilities on site. \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par \tab PROJECT CONDITIONS \par \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Maintain environmental conditions and protect work during and after installation to comply with referenced standards and manufacturer\rquote s printed recommendations. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \fi720\nowidctlpar\widctlpar\adjustright {Vent temporary heaters to exterior to prevent damage to tilework from carbon dioxide build-up. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright { Maintain temperature at not less than 50 degrees F (10 degrees C) in tiled areas during installation and for 7 days after completion, unless higher temperatures are required by referenced installation standards or manufacturer\rquote s written instructions. \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par \par PART 2 PRODUCTS \par }{ \par }{\b \tab ADHESIVE MATERIALS \par }{\i \par }\pard \li720\nowidctlpar\widctlpar\adjustright {ADHESIVE: PLANICRETE W high strength two-component specialty adhesive as manufactured by MAPEI CORPORATION.}{\i \par }\pard \nowidctlpar\widctlpar\adjustright {\i \par *}{\b \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {When specifying PLANICRETE W in performance specification, Call MAPEI CORPORATION\rquote s Technical Service Department toll-free number for assistance with product characteristics. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\i \par When specifying GROUT MATERIALS, refer to respective suggested grout specification \endash ULTRA/COLOR sanded polymer-modified cementitious grout or KER 200 polymer-modified Portland cement tile grout or KER 800 unsanded polymer-modified Portland cement tile grout (ANSI A118.6), or KERAPOXY 100% Solids Epoxy Grout ( ANSI A118.3). ). Grout tiles according to grout instructions and ANSI A108.10 or A108.6 specifications. \par \par }{* \par \par }\pard\plain \s2\fi720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {MIXES \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Mix individually packaged components in accordance with manufacturer\rquote s instructions. \par \par }\pard \nowidctlpar\widctlpar\adjustright { \par }{\b \par PART 3 EXECUTION \par \par }{* \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {Specifications for surface conditions are listed in the beginning of the specification of MAPEI\rquote s Architectural Binder . These specifications should be called out with the related work sections. Delete non-applicable conditions. (Refer to ANSI EXPLANATION AND NOTES section: AN-3 RELATED WORK SPECIFIED IN OTHER SECTIONS.) \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {* \par \par }\pard\plain \s2\fi720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {EXAMINATION \par }\pard\plain \li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par Examine surfaces to receive tilework and conditions under which tile will be installed. Do not proceed with tilework until surfaces and conditions comply with requirements indicated in reference tile installation standards and manufacturer\rquote s printed instructions. \par }\pard \nowidctlpar\widctlpar\adjustright { \par \par \tab }{\b PRPEPARATION}{ \par \tab \par \tab Prepare substrate in accordance with manufacturer\rquote s instructions. \par \tab \par }\pard\plain \s2\fi720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {INSTALLATION \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par \tab Install adhesive in accordance with manufacturer\rquote s printed instructions and ANSI \par \par * \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {There are no TCA methods directly specifying applications of urethane adhesives. Substitute PLANICRETE W where traditional dry-set mortars have been specified. \par \par Select appropriate TCA method to be used and delete non-applicable methods (select from latest edition of TCA Handbook). \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\i *}{ \par \par \tab [Floor Tile: Install in accordance with TCA method [F111], [F112], \par \tab [F112], [F121], [F122], [F141], [TR418], [TR712], [RF912] \par \par \tab [Wall Tile: Install in accordance with TCA method [W221], [W222], \par }\pard \fi720\nowidctlpar\widctlpar\adjustright {[W231], [W241], [TR713].] \par }\pard \nowidctlpar\widctlpar\adjustright { \par \tab [Refrigerator Room Tile: Install in accordance with TCA method R612.] \par \par \tab [Stair Tile: Install in accordance with TCA method S151.] \par \par \tab Install expansion and control joints in accordance with TCA \par \par \tab Grout joints shall be clean and free from standing water, dust and foreign substances. \par \par \tab Tile surfaces shall be clean and dry. \par \par }\pard\plain \s2\fi720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {PROTECTION \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par * \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {Select appropriate statements for installation \endash floor, wall or both. Delete non-applicable statements. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {* \par }\pard \li720\nowidctlpar\widctlpar\adjustright {[Protect floors from general traffic for at least 24 hours after installation.] \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {[Protect walls from impact, vibration and heavy hammering on adjacent and opposite walls for at least 2 days after installation.] \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \fi720\nowidctlpar\widctlpar\adjustright {Protect from freezing and total water immersion for at least 21 days after installation. \par }\pard \nowidctlpar\widctlpar\adjustright { \par \par * \par When dealing with cement-based products, it should be noted that temperature and humidity during and after ins tallation of tile affect final curing time, i.e., low temperatures (60 degrees and under) and high humidity (70% and above) will delay final cure time. \par * \par \par For further information and assistance, contact: \par \par \par }\pard \sa120\nowidctlpar\widctlpar\adjustright {\tab \tab \tab \tab MAPEI CORPORATION \par \tab \tab \tab \tab 1501 WALL STREET \par \tab \tab \tab \tab GARLAND, TEXAS 75041 \endash 4046 \par \tab \tab \tab \tab 1-800-992-6273 \par }}