ASD002. CSI 3-Part Specifications.
MODULAR RAMP SPECIFICATION, 1B, .1.75 TO 2.25 FLUSH
ASD002 Rev May 1995
SPECIFIER NOTE:
THE FOLLOWING DATA IS INTENDED TO ASSIST IN SPECIFYING PEMKO
PRODUCTS. INCORPORATE IN A PROJECT SPECIFICATION WHERE
APPROPRIATE.
CAREFULLY REVIEW TO ENSURE COORDINATION WITH ALL CONTRACT
DOCUMENTS.
1. PRODUCT: MODULAR RAMP THRESHOLD ASSEMBLIES, FLUSH APPLICATION
(1-3/4" TO 2-1/4" OFFSETS)
2. MANUFACTURER:
PEMKO * Ventura PEMKO * Memphis
4226 Transport Street 5535 Distribution Drive
Ventura, CA 93003 Memphis, TN 38141
Phone: (800) 283-9988 Phone (800) 824-3018
Fax: (800) 283-4050 Fax: (800) 243-3656
3. MATERIAL & FINISH:
SPECIFIER NOTE:
PRODUCT SELECTED IS AVAILABLE IN MATERIALS & FINISHES SPECIFIED
BELOW. WHERE MORE THAN ONE MATERIAL IS LISTED FOR A PRODUCT,
SELECT PARAGRAPH FOR MATERIAL YOU WANT.
EDIT BRACKETED TEXT TO SPECIFY FINISH. DELETE TEXT NOT DESIRED.
MATERIALS & FINISHES NOT LISTED MAY BE AVAILABLE BY SPECIAL
ORDER.
RAMP COMPONENTS:
NOTE: PEMKO STRONGLY RECOMMENDS PemKote SKID RESISTANT SURFACE
FOR ALL MODULAR RAMP THRESHOLD ASSEMBLIES. THIS RUGGED ABRASIVE
FINISH IS EXTREMELY SKID AND CORROSION RESISTANT AND CARRIES A
10-YEAR GUARANTEE.
Aluminum, Extruded
* Alloy Type 6063-T5
* Chemical and physical properties per the Aluminum
Association, Inc.
* Federal Specification QQ-A-200/9C.
* [Mill Finish, A; PemKote . AK]
MITER RETURN "WINGS" and EXTENSIONS
Aluminum, Cast
* Alloy Type 6061-F
* Chemical and physical properties per the Aluminum
Association, Inc.
* Federal Specification QQ-A-367.
* [Mill Finish, A; PemKote , AK]
4.TEST & CODE COMPLIANCE:
Handicapped: Complies with CABO/ANSI A117.1-1992; ADA
1990;ADAAG 1991 Guidelines.
Fire Label: Classified By UL For Application To Swinging
Type Fire Doors of the Hollow Metal or Steel
Covered composite type Rated up to 3 Hours, or
Wood Core Fire Doors rated up to 1-1/2
Hours Listed and Labeled as Gasketing
Materials. Tested in accordance with UL10B
by Underwriters Laboratory, Inc. .
5.INSTALLATION:
Installation to be performed in strict accordance with
manufacturers instructions furnished with product.
Ramp Sections: Trim or cope if required. Fasten with No.
10 stainless steel flat head screws provided and
appropriate anchors. Use sealant or compound at all
joints.
Miter Return "Wings": Cut to length as required. Fasten
to ramp component with screws provided. Use sealant or
compound at all edges and joints.
6 WARRANTY:
Guaranteed by manufacturer against defects in material
or workmanship for three years.PemKote Skid-Resistant
surface is guaranteed for 10 years.