ASD032. CSI 3-Part Specifications.
INSTITUTIONAL SYSTEM 3, HOSPITAL SPECIFICATION ASD032 5-95
SPECIFIER NOTE:
THE FOLLOWING DATA IS INTENDED TO ASSIST IN SPECIFYING PEMKO
PRODUCTS. INCORPORATE IN A PROJECT SPECIFICATION WHERE
APPROPRIATE.
CAREFULLY REVIEW TO ENSURE COORDINATION WITH ALL CONTRACT
DOCUMENTS.
1. PRODUCT: PEMKO INSTITUTIONAL SYSTEM No. 3 (HOSPITAL)
2. MANUFACTURER:
PEMKO * Ventura PEMKO * Memphis
4226 Transport Street 5535 Distribution Drive
Ventura, CA 93003 Memphis, TN 38141
Phone:(800) 283-9988 Phone (800) 824-3018
Fax: (800) 283-4050 Fax: (800) 243-3656
3. MATERIAL & FINISH:
SPECIFIER NOTE:
PRODUCT SELECTED IS AVAILABLE IN MATERIALS & FINISHES SPECIFIED
BELOW. WHERE MORE THAN ONE MATERIAL IS LISTED FOR A PRODUCT,
SELECT PARAGRAPH FOR MATERIAL YOU WANT.
EDIT BRACKETED TEXT TO SPECIFY FINISH. DELETE TEXT NOT DESIRED.
MATERIALS & FINISHES NOT LISTED MAY BE AVAILABLE BY SPECIAL
ORDER.
.
AUTOMATIC DOOR BOTTOM: PEMKO No. 4301CPKL
CASE HOUSING:
Aluminum, Extruded
* Alloy Type 6063-T5
* Chemical and physical properties per the Aluminum
Association, Inc.
* Federal Specification QQ-A-200/9C.
* [4301BDGR, Bright Dip Gold Anodized; 4301CR, Clear
Anodized 4301DR, Dark Bronze Anodized]
SEAL:
PemkoPrene , Extruded thermoplastic elastomer
* Flexable between -70 F and +250 F
* Excellent flex fatigue
* Outstanding ozone resistance
PERIMETER GASKETING: PEMKO No.29310CP
HOUSING & SNAP-ON COVER
Aluminum, Extruded
* Alloy Type 6063-T5
* Chemical and physical properties per the Aluminum
Association, Inc.
* Federal Specification QQ-A-200/9C.
* [29310CP, Clear Anodized; 293D10P, Dark Bronze
Anodized; 29310GP, Gold Anodized]
SEAL:
Polyproplyene Pile
* AAMA Specification 701.2
4.TEST & CODE COMPLIANCE:
Fire Label: Classified By UL For Application To Swinging
Type Fire Doors of the Hollow Metal or Steel
Covered composite type Rated up to 3 Hours, or
Wood Core Fire Doors rated up to 1-1/2
Hours Listed and Labeled as Gasketing
Materials. Tested in accordance with UL10B
by Underwriters Laboratory, Inc. .
Smoke Label: Smoke tested by WYLE Laboratories in
accordance with UL 1784-90; meets the
requirements of NFPA 105.
5.INSTALLATION:
Installation to be performed in strict accordance with
manufacturers instructions furnished with product.
Automatic Door Bottom: Cut-down as required and fasten
to door. Adjust for proper contact with floor.
Perimeter Gasketing: NOTE: DO NOT INSTALL SNAP-ON COVERS
UNTIL FINAL ADJUSTMENT IS MADE AND SCREWS TIGHTENED
Fasten to header first, then jambs, ensure contact at
threshold, hold lightly against door and install screws
in center of slots (drill metal frame 7/64" or #36)
Carefully miter or cope at corners to ensure tight
joints and continuous seal. Adjust as required and
tighten screws. Snap on covers.
6 WARRANTY:
Guaranteed by manufacturer against defects in material
or workmanship for three years