{\rtf1\ansi\ansicpg1252\uc1 \deff0\deflang1033\deflangfe1033{\fonttbl{\f0\froman\fcharset0\fprq2{\*\panose 02020603050405020304}Times New Roman;}}{\colortbl;\red0\green0\blue0;\red0\green0\blue255;\red0\green255\blue255;\red0\green255\blue0; \red255\green0\blue255;\red255\green0\blue0;\red255\green255\blue0;\red255\green255\blue255;\red0\green0\blue128;\red0\green128\blue128;\red0\green128\blue0;\red128\green0\blue128;\red128\green0\blue0;\red128\green128\blue0;\red128\green128\blue128; \red192\green192\blue192;}{\stylesheet{\nowidctlpar\widctlpar\adjustright \fs20\cgrid \snext0 Normal;}{\s1\keepn\nowidctlpar\widctlpar\adjustright \b\i\fs20\cgrid \sbasedon0 \snext0 heading 1;}{\s2\keepn\nowidctlpar\widctlpar\adjustright \b\fs20\cgrid \sbasedon0 \snext0 heading 2;}{\s3\li720\keepn\nowidctlpar\widctlpar\adjustright \b\fs20\cgrid \sbasedon0 \snext0 heading 3;}{\*\cs10 \additive Default Paragraph Font;}{\s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid \sbasedon0 \snext15 Body Text;}{ \s16\li5040\nowidctlpar\widctlpar\adjustright \b\fs28\cgrid \sbasedon0 \snext16 Body Text 2;}{\s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid \sbasedon0 \snext17 Body Text Indent 2;}{\s18\li720\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid \sbasedon0 \snext18 Body Text Indent 3;}}{\info{\author Diana Chiodi}{\operator VISCOMM}{\creatim\yr1999\mo5\dy20\hr8\min48}{\revtim\yr1999\mo5\dy20\hr8\min48}{\version2}{\edmins1}{\nofpages4}{\nofwords1228}{\nofchars7003}{\*\company }{\nofcharsws8600} {\vern71}}\widowctrl\ftnbj\aenddoc\formshade\viewkind1\viewscale110\pgbrdrhead\pgbrdrfoot \fet0\sectd \linex0\endnhere\sectdefaultcl {\*\pnseclvl1\pnucrm\pnstart1\pnindent720\pnhang{\pntxta .}}{\*\pnseclvl2\pnucltr\pnstart1\pnindent720\pnhang{\pntxta .}} {\*\pnseclvl3\pndec\pnstart1\pnindent720\pnhang{\pntxta .}}{\*\pnseclvl4\pnlcltr\pnstart1\pnindent720\pnhang{\pntxta )}}{\*\pnseclvl5\pndec\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl6\pnlcltr\pnstart1\pnindent720\pnhang{\pntxtb (} {\pntxta )}}{\*\pnseclvl7\pnlcrm\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl8\pnlcltr\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl9\pnlcrm\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}\pard\plain \fi720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {\tab \tab \tab \tab \tab \tab }{\b INSTALLATION: \par }\pard \li5040\nowidctlpar\widctlpar\adjustright {\b Ceramic, Mosaic, Quarry, Paver, Slate, Marble and Granite\tab \par }\pard \nowidctlpar\widctlpar\adjustright { \par }{\b\fs32 SPECIFICATION}{\fs32 \tab }{\tab \tab \tab }{\b\fs44 KERAPLY}{ \par }\pard\plain \s16\li5040\nowidctlpar\widctlpar\adjustright \b\fs28\cgrid {\b0\fs20 Acrylic Latex Dry-Set Mortar Additive for Ceramic Tiles \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par * \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {DESCRIP TION: An acrylic latex dry-set mortar additive that forms high bond strengths to vitreous and non-vitreous tiles over various substrates, such as concrete and exterior grade plywood when mixed with KERABOND, KERAFLOR, KERASET, or ULTRAFLOR dry-set mortars . (See technical data sheet for additional information). \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard\plain \s18\li720\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid { Specify over properly prepared concrete, cement mortars and leveling coats, masonry block, existing unglazed ceramic tile, paving brick, terrazzo, gypsum wallboard, cement plaster, cementitious backe r units, and exterior grade plywood (dry areas, interior residential floors and countertops only). \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\i \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i Specify for floor and wall applications, except when specified with KERAFLOR (floors only). (See data sheet for details.) \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard\plain \s18\li720\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {Specify for interior and exterior installations. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\i \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i Specify for setting non-vitreous (high absorption) and vitreous (low absorption) ceramic tile mosaics, quarry, paver, slate, and granite.}{ \par }\pard \nowidctlpar\widctlpar\adjustright {\i \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i Specify for applications where improved adhesion, reduced water absorption, greater bond strength, and increased shock and impact resistance is desired.}{ \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i Specify with factory-prepared dry-set mortars on exterior applications to increase freeze/thaw resistance.}{ \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\b\i DO NOT}{\i specify KERAPLY on vertical surfaces with KERAFLOR. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\b\i DO NOT}{\i specify for installation of white or translucent marble. Specify white GRANI/RAPID system (See data sheets for details). \par }\pard \nowidctlpar\widctlpar\adjustright {\i \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\b\i DO NOT}{\i specify for installation of Rosso Levanto and Negro Marquina marble or green marble or granite or their agglomerates. Specify PLANICRETE W or KERAPOXY. (See data sheets for details.) \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\b\i DO NOT}{\i specify over presswood, particleboard, masonite, chipboard, Lauan, gypsum floor patching compounds, metal or similar dimensionally unstable substrates. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard\plain \s18\li720\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {When specifying KERAPLY in the Tile Selection selected - ceramic, mosaic, quarry, paver, slate, marble or granite - add appropriate articles or paragraphs under the applicable }{\b PART}{ as indicated. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {* \par }\pard\plain \s2\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {PART 1 GENERAL \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }\pard\plain \s3\li720\keepn\nowidctlpar\widctlpar\outlinelevel2\adjustright \b\fs20\cgrid {REFERENCES \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {ANSI A108.5 - Installation Specification for Ceramic Tile Installed with Dry-Set Portland Cement Mortar or Latex-Portland Cement Mortar \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }\pard \li720\nowidctlpar\widctlpar\adjustright {ANSI A118.1 - Material Specifications for Dry-Set Portland Cement Mortar \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {ANSI A137.1 - Material Specification for Ceramic Tile \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Tile Council of America, Inc. (TCA) - Handbook for Ceramic Tile Installation \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par }\pard\plain \s3\li720\keepn\nowidctlpar\widctlpar\outlinelevel2\adjustright \b\fs20\cgrid {SUBMITTALS \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {Product Data: Submit manufacturer\rquote s technical information and installation instructions for materials required. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }\pard\plain \s3\li720\keepn\nowidctlpar\widctlpar\outlinelevel2\adjustright \b\fs20\cgrid {QUALITY ASSURANCE \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Provide tile, grout and setting materials from one source. Additives, dry-set mortars, installation materials and grouts shall be from the same manufacturer. \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\b DELIVERY, STORAGE AND HANDLING}{ \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Deliver and store packaged materials from one source. Additives, dry-set mortars, installation materials and grouts shall be from the same manufacturer. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {If frozen, do not stir until material has completely thawed. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Deliver and store materials on site at least 24 hours before work begins. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Provide heated and dry storage facilities on site. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard\plain \s3\li720\keepn\nowidctlpar\widctlpar\outlinelevel2\adjustright \b\fs20\cgrid {PROJECT CONDITIONS \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Maintain environmental conditions and protect work during and after installation to comply with referenced standards and manufacturer\rquote s printed recommendations. \par \par Vent temporary heaters to exterior to prevent damage to tile work from carbon dioxide build-up. \par \par Maintain temperature at not less than 50 degrees F (10 degrees C) in tiled areas during installation and for 7 days after completion, unless higher temperatures are required by referenced installation standards or manufacturer\rquote s printed inst ructions. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }{\b PART 2 PRODUCTS \par }{ \par *\tab \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {Select KERABOND, KERAFLOR, KERASET or ULTRA/FLOR with KERAPLY when specifying LATEX-PORTLAND CEMENT MORTAR (see data sheets). Delete non-applicable dry-set mortars. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\i *}{ \par \par }\pard\plain \s3\li720\keepn\nowidctlpar\widctlpar\outlinelevel2\adjustright \b\fs20\cgrid {MORTAR MATERIALS \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {LATEX-PORTLAND CEMENT MORTAR: KERAPLY, Setting system consisting of two components: KERAPLY acrylic latex additive and [KERA BOND], [KERAFLOR], [KERASET], [ULTRA/FLOR] factory prepared dry-set mortar, ANSI A118.4, as manufactured by MAPEI CORPORATION. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }{* \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {When specifying KERAPLY in performance specification, call MAPEI CORPORATION\rquote s Technical Service Department toll-free number for assistance with product characteristics.}{\i0 \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\i \par When specifying GROUT MATERIALS, refer to respective suggested grout specification - ULTRA/COLOR sanded polymer-modified cemen titious grout or KER 200 sanded polymer-modified Portland cement tile grout or KER 800 unsanded polymer-modified Portland cement tile grout (ANSI A118.6) or KERAPOXY 100% solids epoxy grout (ANSI A118.3). Grout tiles according to grout instructions and A NSI A108.10 or A108.6 specifications. \par }{* \par \par }\pard\plain \s2\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {MIXES \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {Proportion and mix factory-prepared mortar with acrylic latex additive in accordance with manufacturer\rquote s printed instructions. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }{\b PART 3 EXECUTION \par }{ \par * \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {Specifications for surface conditions are listed in the beginning of the specification of MAPEI\rquote s Architectural Binder. These specifications shoul d be called out with the related work sections. Delete non-applicable conditions. (Refer to ANSI EXPLANATION AND NOTES section: AN-3 RELATED WORK SPECIFIED IN OTHER SECTIONS.) \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {* \par \par }\pard\plain \s2\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {EXAMINATION \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard \li720\nowidctlpar\widctlpar\adjustright { Examine surfaces to receive tile work and conditions under which tile will be installed. Do not proceed with tile work until surfaces and conditions comply with requirements indicated in referenced tile installation standard and manufacturer\rquote s printed instructions. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard\plain \s2\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {INSTALLATION \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Install tile in accordance with manufacturer\rquote s printed instructions and ANSI A108.5 \par }\pard \nowidctlpar\widctlpar\adjustright { \par * \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {Select TCA method to be used and delete non-applicable methods. (Select from latest edition of the TCA Handbook.) \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\i * \par }{ \par }\pard \fi720\nowidctlpar\widctlpar\adjustright {Floor Tile: Install in accordance with TCA method \par }\pard \li720\nowidctlpar\widctlpar\adjustright {[F101], [F102], [F103], [F111], [F112], [F113], [F114], \par }\pard \fi720\nowidctlpar\widctlpar\adjustright {[F115], [F121], [F122], [F141], [TR712], [TR912.].] \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \fi720\nowidctlpar\widctlpar\adjustright {[Wall Tile: Install in accordance with TCA method \par [W201], [W202], [W211], [W221], [W222], [W231], [W241], \par [W243], [W244], [B412], [B413], [B414], [B415], [TR713].] \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {[Countertop Tile: Install in accordance with TCA method [C511], [C512], [C513].] \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Install expansion and control joints in accordance with TCA method EJ171. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Grout joints shall be clean and free from standing water, dust and foreign substances. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {Tile surfaces shall be clean and dry. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard\plain \s2\li720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {PROTECTION \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par * \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {Select appropriate statements for installation \endash floor, wall or both. Delete non-applicable statements. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {* \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid { [Protect floors from general traffic for at least 72 hours after installation. Plywood or stepping boards may be used after 24 hours when occasional stepping on the floor is unavoidable.] \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {[Protect walls from impact, vibration and heavy hammering on adjacent and opposite walls for at least 14 days after installation.] \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {Protect from freezing and total water immersion for at least 21 days after installation. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par * \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid { When dealing with cement-based products, it should be noted that temperature and humidity during and after installation of tile affect final curing time, i.e., low temperatures (60 degrees and under) and high humidity (70% a nd above) will delay final cure time. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {* \par \par For further information and technical assistance, contact: \par \par }\pard \sa120\nowidctlpar\widctlpar\adjustright {\tab \tab \tab \tab MAPEI CORPORATION \par \tab \tab \tab \tab 1501 WALL STREET \par \tab \tab \tab \tab GARLAND, TEXAS 75041 \endash 4046 \par \tab \tab \tab \tab 1-800-992-6273 \par }}