PC Series. CSI 3-Part Specifications.
PC SERIES DETAILS AND SPECIFICATIONS
1. Scope
1.1 Product
Furnish Durasteel Model PC ______ as manufactured by Porta-King Building Systems, or pre-approved equal.
2. Materials
2.1 Product Construction
Building to be of welded steel construction with all intersecting welded connections ground smooth. Overall height to be 89 1/2" for interior
use; or 91 1/2" with exterior roof.
2.2 Structural Framework
Structural corner and uprights to be 2" x 2" x .120 structural ASTM A500 Grade B welded tubing.
2.3 Wall Panels
Wall panels to be pan type construction made from 14 gauge galvanized steel on exterior and flat 16 gauge galvanized steel on interior.
Panels to be mechanically fastened to framework to allow field replacement of damaged panels. Overall wall thickness to be 2" and shall be
insulated to R-9.
2.4 Finish
All surfaces to be electrostatically painted with rust inhibitive epoxy primer and to have a finish coat of air-dry industrial acrylic paint. Building
to be painted one color as selected from standard acrylic finishes.
2.5 Floor Structure
Floor to be 1 1/2" solid waterproof insulating core fit tight against wall panels and fastened to bottom 12 gauge galvanized structural base
frame. The finished floor to be maintenance-free 3003 TREADBRITE aluminum safety treadplate.
2.6 Ceiling
Ceiling to be a composite panel. Roof to be insulated to R-17 and to include a protective membrane on top side.
2.7 Doors
Doors to be of anodized aluminum, 1 3/4" thick, half-glazed with clear tempered safety glass. Bottom portion to include insulated panel with
smooth anodized aluminum on both sides.
2.7.1 Sliding door to be top-suspended in overhead track assembly and to be fully weatherstripped. Sliding doors to incorporate a maximum security laminated hookbolt deadlock with removable cylinders. Door to be recessed into the floor structure.
2.7.1 Swing door to be fully weatherstripped with key-in-knob lockset.
2.7.2 Transaction booths to have horizontal sliding cashier window in the door.
2.8 Windows
Windows to have aluminum frames. Sliding windows to include an inside positive locking device. Exterior window sill height to be 38" (inside
34" from finished floor).
2.9 Glass-Glazing
All glazing to be tempered/safety glass.
2.10 Counter
Furnish 22" deep, full width counter, 32" from finished floor and walnut grain plastic laminate.
2.11 Electrical Service
All components to bear UL label. Electric service to include single phase, 100 AMP capacity load center, pre-wired in conduit, with one (1)
230v and four (4) 115v circuit capability. Furnish one (1) 115v duplex and one (1) 230v single outlets. Electric work to be in conformation with
the NEC. Provide one (1) 6" x 12" conduit access cutout, with removable cover, in the floor.
2.11.1 Lights to be fluorescent type fixtures with acrylic lens.
2.12 Exterior Roof
Exterior weatherproof roof to be of 14 gauge galvanized steel and to include a 3" overhang with a 6" fascia. Roof to be shipped installed.