Safety Ladder Specification Page - 1. CSI 3-Part Specifications.
JOMY SAFETY LADDER SPECIFICATION GUIDE
This section is based on products distributed by JOMY Safety Products, Inc., at the following address:
6255 Longbow Drive
Boulder, CO 80301
Telephone:(303) 527-2700
(800) 255-2591
Fax: (303) 527-2800
The JOMY Safety Ladder is intended for emergency exit or rescue or for mechanical equipment access. Looking like an ordinary drainpipe when closed, a quarter turn of a handle deploys a 2-foot-wide industrial strength ladder with slip-resistant rungs and a safety rail. A JOMY balcony is available to supplement access to the ladder where required.
PART 1. GENERAL
1.1. SECTION INCLUDES
A. | Retractable exit ladders for use as supplemental escape devices. |
B. | Retractable ladder devices to provide access to mechanical equipment. |
1.2 REFERENCES
A. | Evaluation Reports; Building Officials and Code Administrators International, Inc. (BOCA). |
B. | Evaluation Reports; International Conference of Building Officals (ICBO). |
C. | Uniform Building Code; International Conference of Building Officials (ICBO). |
D. | Uniform Fire Code; International Conference of Building Officials (ICBO). |
E. | Uniform Mechanical Code; International Conference of Building Officials (ICBO). |
F. | Uniform Building Code Standards; International Conference of Building Officials (ICBO). |
G. | Underwriters Laboratories Inc. (UL). |
1.3 SUBMITTALS
A. | Submit under provisions of Section 01300. |
B. | Product Data: Provide manu-facturers standard details and catalog data demonstrating compliance with referenced standards. Provide installation instructions. |
C. | Shop Drawings: Submit drawings showing overall height of ladders, and location of deployment handles in relation to floor elevations, window sills and railings. |
D. | Warranty: Submit manufacturers standard warranty |
1.4 DELIVERY, STORAGE, HANDLING
A. Store products indoors and protect from moisture, construction traffic, and damage. |
1.5 WARRANTY
A. | Manufacturers standard warranty against defects in materials and workmanship; 10 year period. |
PART 2. PRODUCTS
2.1 MANUFACTURER
A. | Provide products fabricated by JOMY Safety Products,
Inc., 6255 Longbow Drive, Boulder, CO 80301. |
2.2 MATERIALS
A. | Stiles: Extruded Aluminum, 6063-T6 alloy. |
B. | Rungs: Extruded aluminum, 6005-T5 alloy and 6005-T6 alloy. |
C. | Brackets: 6063-T6 aluminum alloy. |
D. | Pivot pins, Springs, Masonry Bolts, Fasteners and Base Plate: Stainless Steel |
2.3 LADDERS
A. | General:
|
||||||||||
B. | Certifications
|
||||||||||
C. | Provide dual safety rails at ladders with access from both sides. | ||||||||||
D. | Provide reinforcement channel where ladders extend beyond wall support, such as at parapets and roof tops, or where ladder spans open areas in excess of 7 feet between attachment points. | ||||||||||
E. | Shop fabricate and assemble to maximum extent practicable for installation on-site with minimal labor. |
2.4. ACCESSORIES
A. | Provide brackets, spacers, etc., necessary for a complete installation. |
B. | Provide removable deployment handle at lower access point; provide locking hub and padlock. |
C. | Contractor to provide fasteners for securement to wood construction: Stainless steel lag bolts; 3/8-inch diameter, 4-inch minimum embedment. |
D. | Contractor to provide fasteners for securement to steel construction: Stainless steel bolts, nuts, and washers; 3/8-inch diameter. |
2.5 FINISHES
A. | Aluminum: Clear anodized. | ||||
B. | Manufacturers standard shop-applied
enamel.
|
PART 3. EXECUTION
3.1 EXAMINATION
A. | Verify that wall surfaces to receive units are complete and approved prior to installing work of this section. |
3.2 INSTALLATION
A. | Install components in strict compliance with manufacturers instructions. |
3.3 ADJUST AND CLEAN
A. | Remove debris; leave project site in clean and orderly condition. |