Kemlite. CSI 3-Part Specifications.
SECTION 09986 SANITARY WALL FINISH
KEMLITE® FIBERGLASS REINFORCED PLASTIC PANELS.
PART 1: GENERAL
1.01 DESCRIPTION
This section describes the requirements for furnishing and installing fiberglass reinforced plastic panels according to manufacturer's recommendations.
1.02 SUBMITTALS:
Submit in accordance with Section (Insert Section Number)
- Two samples of each type of panel each type of trim and fastener.
- Shop Drawings: Indicate the location and dimension of joints and fastener attachment.
- Installation Guide #6211.
1.03 QUALITY ASSURANCE
Provide panels and molding only from the manufacturer specified to ensure warranty and color harmonization of accessories.
1.04 DELIVERY, STORAGE, AND HANDLING:
- Delivery of Materials: Package sheets on skids or pallets for shipment to project site.
- Storage of Materials: Store panels indoors in a dry place at the project site.
- Handling: Remove foreign matter from face of panel by use of a soft bristle brush, avoiding abrasive action.
1.05 PROJECT CONDITIONS:
- Installation shall not begin until building is enclosed, permanent heating and cooling equipment is in operation, and residual moisture from plaster, concrete or terrazzo work has dissipated
- During installation and for not less than 48 hours before, maintain an ambient temperature and relative humidity within limits required by type of adhesive used and recommendation adhesive manufacturer.
- Provide ventilation to disperse fumes during application of adhesive as recommended by the adhesive manufacturer.
SECTION 09986 SANITARY WALL FINISH
KEMLITE® FIBERGLASS REINFORCED PLASTIC PANELS.
PART 2: PRODUCTS
2.01 MATERIALS
- Acceptable panels: (Insert from Item 1,2,3 or 4 Part A.)
- Division Bars, Corner Trim: Panel manufacturer's standard length extruded vinyl pieces; longest length possible - to eliminate end joints (Insert from Item 1,2,3, or 4 Part B)
- Fasteners: Non-corrosive drive rivets. (Insert from Item 1,2, or 3 Part C.)
PART 3: EXECUTION
3.01 PREPARATION
- Examine backup surfaces to determine that corners are plumb and straight, surfaces are smooth, uniform, clean and free from foreign matter, nails countersunk, joints and cracks filled flush and smooth with the adjoining surface.
- Do not begin installation until backup surfaces are put into satisfactory condition.
3.02 APPLICATION
- Do all cutting and drilling with carbide tipped saw blades or drill bits, or cut with snips.
- Install panels with manufacturer's recommended gap for panel field and corner joints.
- Fastener holes in the panels must be predrilled 1/8" (3.2 mm) oversize.
- For trowel type and application of adhesive, follow adhesive manufacturers recommendation.
- Using products acceptable to manufacturer, install the frp panel system in accordance with panel manufacturer's printed instructions, Installation Guide #6211.
3.03 CLEANING.
- Remove any adhesive or excessive sealant from panel face using solvent or cleaner recommended by panel manufacturer.
March 3, 1999
Form# 6259, REV 3 (98-192)
Kemlite, are registered trademarks of Kemlite Company, Inc.
ATTACHMENT ITEM 1
Product Specifications -- Fire-X Glasbord® Fiberglass Panels with Surfaseal®
PART 2: PRODUCTS
2.01 MATERIALS:
- Class I (A) Interior Finish. Wall and/or ceiling panels shall be KEMLITE® Fire-X Glasbord with Surfaseal fiberglass reinforced plastic panels as manufactured by KEMLITE COMPANY, Joliet, Illinois, USA Phone: 1-800-435-0080 or 1-815-467-8600, Fax: 1-815-467-8666.
- WALL PANELS
Finish, thickness and color to be: (choose one of the following)
- embossed .09" (2.3mm) Fire-X Glasbord with Surfaseal
color: 85 white
83 colonial white
70 soft beige
48 pearl gray
66 silver
84 ivory
b. embossed. 12" (3.0mm) Fire-X Glasbord with Surfaseal
color: 85 white
c. smooth .075" (1.9mm) Glasbord-FSI with Surfaseal
color: 85 white
2. LAY-IN CEILING PANELS
Finish, thickness and color to be: (choose one of the following)
a. embossed .09" (2.3mm) Fire-X Glasbord with Surfaseal
color: 85 white
b. embossed .12" (3.0mm) Fire-X Glasbord with Surfaseal
color: 85 white
Alternate products shall meet or exceed the following Fire-X Glasbord properties:
- Underwriter's Laboratories (UL.) Classified - embossed FXI .09" (2.3mm) only.
- Class A Flame Spread of less than 25, Smoke Developed less than 450 per ASTM-E84 latest version.
- Barcol Hardness (scratch resistance) of 55 as per ASTM D-2583
- Panels with exhibit no more than a 0.038% weight loss after a 25-cycle Taber Abrasion Test using CS-17 abrasive wheels with 1000 g. wt.
- Gardner Impact Strength of 22 in. - lbs. (25.6 cm - kg) showing no visible damage on front side per ASTM D-3029.
- FMRC (Factory Mutual Research Center) approved. Subject to the conditions of approval as described in FMRC Report J.I. IV549.AM-embossed FXI .09" only.
- Meets USDA / FSIS Requirements.
- ICBO Report Number 4583.
- A means of frontside identification and confirmation of meeting Class I (A) interior finish requirements after installation and while in service (without labels)-embossed FXI only.
Numerical flame spread and smoke development ratings are not intended to reflect hazards presented by Kemlite Company products or any other materials under actual fire conditions. These ratings are determined by small scale tests conducted by independent testing facilities using the American society for Testing and Materials E-84 test standard (commonly referred to as the "Tunnel Test"). KEMLITE PROVIDES THESE RATINGS FOR MATERIAL COMPARISON PURPOSES ONLY. Like other organic building materials (e.g. wood), panels made of fiberglass reinforced plastic will burn. When ignited, frp may produce dense smoke very rapidly. All smoke is toxic. Fire safety requires proper design of facilities and fire suppression systems. as well as precaustions during construction and occupancy. Local codes, insurance requirements and any special needs of the user of the product will determine the correct fire-rated interior finish and fire suppression system necessary for a specific installation.
2.01 MATERIALS:
Part A: (continued)
- Special colors can be custom matched and manufactured provided there is a minimum square footage order of 12,000 square feet (1,115 square meters). Please call for quote and allow 4-6 weeks lead time.
- Standard sizes are 4' x 8', 9', 10' and 12' (1.2m x 2.4m, 2.7m 3.0m and 3.7m). Ceiling panels of 2' x 4' and 2' x 2' (.6m x 1.2m, .6m x .6m).
- Embossed Fire-X Glasbord panels are identified by trademarked blue and red threads manufactured into the back of the panel and trademarked dual florescent embedded threads on the front of the panel (visible only under UV light).
B. Moldings: Harmonizing PVC (polyvinyl chloride) moldings shall be: (Enter color from list below)
85 white
83 colonial white
70 soft beige
48 pearl gray
66 silver
84 ivory
- Rivets: Optional. Specify rivets in harmonizing colors (by color name and number) in areas where there are large changes in temperature and/or humidity, where the substrate is unusually uneven, and in all low temperature or cold storage applications. Refer to Installation Guide #6211 for rivet pattern and installation instructions.
- Local distributor list attached or: (Please include if job is local).
Name:
Address:
Telephone:
Contact:
For current distribution and technical information, please call or write: Kemlite Company, Inc., P.O. Box 2429, Joliet, IL 60434, (800) 435-0080, (815) 467-8600, FAX (815) 467-8666.
Kemlite, Glasbord, Fire-X Glasbord, Surfaseal, Thread on the backside and Florescent Thread on the Frontside are registered trademarks of Kemlite Company, Inc.
ATTACHMENT ITEM 2
Product Specifications -- Glasbord® -P Fiberglass Panels with Surfaseal®
PART 2: PRODUCTS
2.01 MATERIALS:
A. Class III (C) Interior Finish. Wall and/or ceiling panels shall be KEMLITE® Glasbord with Surfaseal fiberglass reinforced plastic panels as manufactured by KEMLITE COMPANY, Joliet, Illinois, USA
Phone: 1-800-435-0080 or 1-815-467-8600, Fax: 1-815-467-8666.
1. WALL PANELS
Finish, thickness and color to be: (choose one of the following)
a. embossed .09" (2.3mm) Glasbord-P with Surfaseal
color: 85 white
83 colonial white
70 soft beige
48 pearl gray
66 silver
84 ivory
b. embossed .12" (3.0mm) Glasbord-PWI with Surfaseal
color: 85 white
c. smooth .075" (1.9mm) Glasbord-PSI Glasbord-PSI with Surfaseal
color: 85 white
2. LAY-IN CEILING PANELS
Finish, thickness and color to be: (choose one of the following)
a. embossed .10" (2.5mm) Glasbord-CGI with Surfaseal
color: 85 white
b. embossed .12" (3.0mm) Glasbord-PWI with Surfaseal
color: 85 white
Alternate products shall meet or exceed the following Glasbord properties:
1. Class C Flame Spread of 200 or less, Smoke Developed of 450 or lower per ASTM E-84 latest version.
2. Barcol Hardness (scratch resistance) per ASTM D-2583 of:
- 42 for embossed .09" (2.3mm) Glasbord-P
- 55 for embossed .12" (3.0mm) Glasbord-PWI
- 55 for smooth .075" (1.9mm) Glasbord-PSI
- 60 for embossed .10" (2.5mm) Glasbord-CGI
3. Panels will exhibit no more than a 0.038% weight loss after a 25-cycle Taber Abrasion Test using CS-17 abrasive wheels with 1000 g. wt.
4. Gardner Impact Strength of 16 in. - lbs. (19 cm - kg) with no visible damage to front side for Glasbord-P and Glasbord-CGI, and 18 in. - lbs. (21 cm - kg) for Glasbord PSI per ASTM D-3029
5. Meets USDA / FSIS Requirements.
6. ICBO Report Number 4583.
7. A means of frontside identification and confirmation of meeting Class III (C) the interior finish requirement after installation and while in service (without labels) - embossed panels only.
Numerical flame spread and smoke development ratings are not intended to reflect hazards presented by Kemlite Company products or any other material under actual fire conditions. These ratings are determined by small scale tests conducted by independent testing facilities using the American Society for Testing and Materials E-84 test standard (commonly referred to as the "Tunnel Test").
KEMLITE PROVIDES THESE RATINGS FOR MATERIAL COMPARISON PURPOSES ONLY. Like other organic building materials (e.g. wood), panels made of fiberglass reinforced plastic will burn. When ignited, frp may produce dense smoke very rapidly. All smoke is toxic. Fire safety requires proper design of facilities and fire suppression systems, as well as precautions during construction and occupancy. Local codes, insurance requirements and any special needs of the user of the product will determine the correct fire-rated interior finish and fire suppression system necessary for a specific installation.
- Special colors can be custom matched and manufactured provided there is a minimum square footage order of 12,000 square feet (1,115 square meters). Please call for quote and allow 4-6 weeks lead time.
- Standard sizes are 4' x 8', 9', 10' and 12' (1.2m x 2.4m, 2.7m, 3.0m and 3.7m). Ceiling panels of 2' x 4 and 2' x 2' (.6m x 1.2m, 6m x 6m).
- Embossed Glasbord-P, Glasbord-PWI and Glasbord-CGI panels are identified by trademarked black threads manufactured into the back of the panel and a trademarked single florescent embedded thread on the front of the panel (visible only under UV light).
B. Moldings: Harmonizing PVC (polyvinyl chloride) moldings shall be: (Enter color from list below)
85 white
83 colonial white
70 beige
48 pearl gray
66 silver
84 ivory
C. Rivets: Optional. Specify rivets in harmonizing colors (by color name and number) in areas where there are large changes in temperature and/or humidity, where the substrate is unusually uneven, and in all low temperature or cold storage applications. Refer to Installation Guide #6211 for rivet pattern and installation instructions.
D. Local Distributor List Attached or: (Please include if job is local).
Name:
Address:
Telephone:
Contact:
For current distribution and technical information, please call or write: Kemlite Company, Inc., P.O. Box 2429, Joliet, IL 60434, (800) 435-0080, (815) 467-8600, FAX (815) 467-8666.
Kemlite, Glasbord, Surfaseal, Thread on the backside and Florescent Thread on the Frontside are registered trademarks of Kemlite Company, Inc.
ATTACHMENT ITEM 3
Product Specifications -- Kemply® Fiberglass Laminated Panel with Surfaseal®
PART 2: PRODUCTS
2.01 MATERIALS:
A. Wall and / or ceiling panels shall be KEMLITE Kemply with Surfaseal fiberglass reinforced plastic panels as manufactured by KEMLITE COMPANY, Joliet, Illinois, USA
Phone: 1-800-435-0080 or 1-815-467-8600, Fax: 1-815-467-8666.
1. WALL PANELS
Wall panels shall be: (choose one substrate from chart below) substrate with a factory laminated white (choose one skin from chart below) skin, size to be (4 ft x 8 ft x 4 ft x 10 ft) and skin (single or double) sided.
SUBSTRATES
GYPSUM |
1/2" Regular |
5/8" Firecode-X |
PLYWOOD |
3/8" BCX - Fir |
1/2" BCX - Fir |
5/8" BCX - Fir |
EXPANDED POLYSTYRENE FOAM |
1# 1" thick EPS-Open Cell |
1# 2" thick EPS-Open Cell |
EXTRUDED POLYSTYRENE FOAM |
2.5# 1" thick XEPS-Closed Cell |
2.5# 2" thick XEPS-Closed Cell |
ORIENTED STRAND BOARD |
1/4" OSB |
9/32" OSB |
1/2" OSB |
FLUTED POLYPROPYLENE* |
.32" black |
.32" white |
.40" black |
.40" white |
ALUMINUM BACKED XEPS FOAM |
2.5# 1" thick - XEPS closed cell |
2.5# 2" thick - XEPS closed cell |
AVAILABLE SKINS
CLASS C |
.05" embossed Glasbord-PWI |
.09" embossed Glasbord-PIF |
.075" smooth Glasbord-PSI |
CLASS A |
.09" embossed Fire-X Glasbord |
.075" smooth Glasbord-FSI |
* In areas of extreme temperature (over 100 �F) Kemply polypropylene panels must be laminated on both sides with Glasbord frp skins to avoid warping. Lay-in ceiling panels should be laminated on both sides for all installations.
Note: Standard Kemply panel is 9/32" OSB with .05" Glasbord-PWI skin single sided. All other Kemply products are made to order and are non-cancelable.
2. LAY-IN CEILING PANELS
Lay-in ceiling panels shall be: (choose one substrate from chart below) substrate with a factory laminated white (choose one skin from chart below) skin, size to be (23.75" x 23.75" or 23.75" x 47.75") and skin (single or double) sided.
SUBSTRATES
GYPSUM |
1/2" Regular* |
5/8" Firecode-X * |
*single sided available only with .05" skin |
EXPANDED POLYSTYRENE FOAM |
1# 1" thick EPS-Open Cell** |
1# 2" thick EPS-Open Cell** |
** available with .05" double sided skin only |
FLUTED POLYPROPYLENE |
.32" black ** |
.32 white ** |
.40" black ** |
.40" white ** |
** available with .05" double sided skin only |
EXTRUDED POLYSTYRENE FOAM |
2.5# 1" thick XEPS-Closed Cell*** |
2.5# 2" thick XEPS-Closed Cell*** |
*** available with .05" double sided Glasbord-PWI skin, double sided .09" Fire-X Glasbord and .075" Glasbord-FSI skin only |
AVAILABLE SKINS
CLASS C |
.05" embossed Glasbord-PWI |
.09" embossed Glasbord-PIF |
.075" smooth Glasbord-PSI |
CLASS A |
.09" embossed Fire-X Glasbord |
.075" smooth Glasbord-FSI |
All ceiling panels are made to order and are non-cancelable
1. All panels meet USDA / FSIS Requirements.
The 3/32" OSB with .05" Glasbord-PWI skin single side has been tested to comply with Class C requirements. With variation in substrates, the other Kemply panels above are not tested for physical properties or fire resistance. All Glasbord finishes have been tested for surface burning characteristics (See Kermlite Technical Bulletins 65024, 6229, and 6283). Physical properties and fire resistance data on the substrate are available from the specific substrate manufacturer. Kemlite makes no representation or warranty as to the composite panel fitness for any specific application, overall physical properties, fire resistance, or burning characteristics.
Numerical flame spread and smoke development ratings are not intended to reflect hazards presented by Kemlite Company products or any other material under actual fire conditions. These ratings are determined by small-scale tests conducted by independent testing facilities using the American Society for Testing and Materials e-84 test standard (commonly referred to as the "Tunnel Test"). KEMLITE PROVIDES THESE RATINGS FOR MATERIAL COMPARISON PURPOSES ONLY. Like other organic building materials (e.g. wood), panels made of fiberglass reinforced plastic with burn. When ignited, frp may produce dense smoke very rapidly. All smoke is toxic. Fire safety requires proper design of facilities and fire suppression systems, as well as precautions during construction and occupancy. Local codes, insurance requirements and any special needs of the user of the product will determine the correct fire-rated interior finish and fire suppression system necessary for a specific installation.
For current distribution and technical information, please call or write: Kemlite Company, Inc., P.O. Box 2429, Joliet, IL 60434, (800) 435-0080, (815) 467-8600, FAX (815) 467-8666.
Kemlite, Glasbord, Fire-X Glasbord, Kemply, Surfaseal, are registered of Kemlite Company, Inc.
SECTION 09120 CEILING ORID SYSTEM
KEMLITE® SANIGRID®
PART 1: GENERAL
1.01 DESCRIPTION:
This section describes the requirements for furnishing and installing fiberglass reinforced ceiling grid according to manufacturer's recommendations.
1.02 SUBMITTALS:
Submit in accordance with Section (Insert Section Number)
- Two samples of each grid member and attachment clip.
- Shop Drawings: Indicate the location of main tees and cross tees.
- Installation Guide #6244.
1.03 QUALITY ASSURANCE
Provide grid and clips only from the manufacturer specified to ensure warranty.
1.04 DELIVERY, STORAGE, AND HANDLING:
A. Delivery of Materials: Deliver grid and accessories in manufacturer's unopened cartons.
B. Storage of Materials: Store cartons in a dry place at the project site.
1.05 PROJECT CONDITIONS:
A. Installation shall not begin until building is enclosed, permanent heating and cooling equipment is in operation, and residual moisture from plaster, concrete or terrazzo work has dissipated.
B. During installation and for not less than 48 hours before, maintain an ambient temperature and relative humidity similar to what will be the normal operating conditions of the room.
PART 2: PRODUCTS
2.01 MATERIALS:
Sanigrid Pultruded Fiberglass Reinforced Plastic Grid System, manufactured for KEMLITE COMPANY, Joliet, Illinois, U.S.A. Phone 1-800-435-0080 or 1-815-467-8600, Fax: 1-815-467-8666.
Main Tee |
Part # SG101 |
4 ft. Cross Tee |
Part # SG102 |
2 ft. Cross Tee |
Part # SG122 |
Wall Angle |
Part # SG103 |
Junction Clips |
Part # C-2 For systems including Glasbord ceiling panels |
Part # C-3 For systems including non-frp ceiling panels |
|
Connector Clips |
Part # C-1 |
Hold Down Clips |
Part # C-4 For use with ceiling panels up to 1" thick |
Part # C-5 For use with ceiling panels over 1" thick |
Color: Grid Members - manufacturer's standard white
Clips - manufacturer's standard blue
Sanigrid products shall meet or exceed the following properties:
1. Meets Class A finish requirements: Flame spread of less than 25, smoke developed less than 450 per ASTM E-84 latest version.
2. Meets USDA /FSIS requirements.
3. Genuine Kemlite Sanigrid identified by a single black thread embedded in the vertical leg of the tees.
3.01 PREPARATION:
A. Ensure that all HVAC, electrical, plumbing and similar work above the ceiling level has been completed.
3.02 APPLICATION:
A. Do all cutting with carbide tipped saw blade.
B. Install per manufacturer's printed instructions, Installation Guide #6244.
Sanigrid, Kemlite, are registered trademarks of Kemlite Company, Inc.