{\rtf1\ansi\ansicpg1252\uc1 \deff0\deflang1033\deflangfe1033{\fonttbl{\f0\froman\fcharset0\fprq2{\*\panose 02020603050405020304}Times New Roman;}}{\colortbl;\red0\green0\blue0;\red0\green0\blue255;\red0\green255\blue255;\red0\green255\blue0; \red255\green0\blue255;\red255\green0\blue0;\red255\green255\blue0;\red255\green255\blue255;\red0\green0\blue128;\red0\green128\blue128;\red0\green128\blue0;\red128\green0\blue128;\red128\green0\blue0;\red128\green128\blue0;\red128\green128\blue128; \red192\green192\blue192;}{\stylesheet{\nowidctlpar\widctlpar\adjustright \fs20\cgrid \snext0 Normal;}{\s1\keepn\nowidctlpar\widctlpar\adjustright \b\i\fs20\cgrid \sbasedon0 \snext0 heading 1;}{\s2\keepn\nowidctlpar\widctlpar\adjustright \b\fs20\cgrid \sbasedon0 \snext0 heading 2;}{\s3\li720\keepn\nowidctlpar\widctlpar\adjustright \b\fs20\cgrid \sbasedon0 \snext0 heading 3;}{\*\cs10 \additive Default Paragraph Font;}{\s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid \sbasedon0 \snext15 Body Text;}{ \s16\li5040\nowidctlpar\widctlpar\adjustright \b\fs28\cgrid \sbasedon0 \snext16 Body Text 2;}{\s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid \sbasedon0 \snext17 Body Text Indent 2;}}{\info{\author Diana Chiodi}{\operator VISCOMM} {\creatim\yr1999\mo5\dy19\hr17}{\revtim\yr1999\mo5\dy19\hr17}{\version2}{\edmins1}{\nofpages4}{\nofwords1195}{\nofchars6812}{\*\company }{\nofcharsws8365}{\vern71}}\widowctrl\ftnbj\aenddoc\formshade\viewkind1\viewscale110\pgbrdrhead\pgbrdrfoot \fet0 \sectd \linex0\endnhere\sectdefaultcl {\*\pnseclvl1\pnucrm\pnstart1\pnindent720\pnhang{\pntxta .}}{\*\pnseclvl2\pnucltr\pnstart1\pnindent720\pnhang{\pntxta .}}{\*\pnseclvl3\pndec\pnstart1\pnindent720\pnhang{\pntxta .}}{\*\pnseclvl4 \pnlcltr\pnstart1\pnindent720\pnhang{\pntxta )}}{\*\pnseclvl5\pndec\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl6\pnlcltr\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl7\pnlcrm\pnstart1\pnindent720\pnhang{\pntxtb (} {\pntxta )}}{\*\pnseclvl8\pnlcltr\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}{\*\pnseclvl9\pnlcrm\pnstart1\pnindent720\pnhang{\pntxtb (}{\pntxta )}}\pard\plain \fi720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {\tab \tab \tab \tab \tab \tab }{ \b GROUTING: \par }\pard \li5040\nowidctlpar\widctlpar\adjustright {\b Ceramic, Mosaic, Quarry, Paver, Slate and Granite \par \par }\pard \nowidctlpar\widctlpar\adjustright {\b\fs32 \par }\pard\plain \s16\nowidctlpar\widctlpar\adjustright \b\fs28\cgrid {\b0\fs32 SPECIFICATION}{\fs32 \tab }{\tab \tab \tab }{\fs44 2 1/2 TO 1}{\fs20 \par \tab \tab \tab \tab \tab \tab \tab }{\b0\fs20 Large Joint Filler/ Sautillo Grout \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par * \par }{\b\i DESCRIPTION:}{\i A grouting compound designed to fill large grout joints that are usually associated with terracotta tile, such as Mexican, Brazilian, and Spanish tiles. \par \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i Specify for grouting high absorptive tile with joint widths from 3/8\rdblquote to 3/4\rdblquote (10mm to 19mm). \par }\pard \nowidctlpar\widctlpar\adjustright {\i \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i Specify for interior or exterior floor and wall installations. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i Specify grouting tiles set over exterior grade plywood (interior residential dry floors and countertops only), steel and KERAFONIC sound deadening underlayment, when mixed with PLASTIJOINTS acrylic latex grout additive. \par }\pard \nowidctlpar\widctlpar\adjustright {\i \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i Specify 2 1/2 to 1 Grout with PLASTIJOINTS acrylic latex grout additive instead of water for increased strength, density, flexibility, freeze/thaw resistance and decreased water absorption. \par \par }{\b\i DO NOT}{\i specify for joints narrower than 3/8\rdblquote . Specify ULTRA/COLOR, KERACOLOR WALL or FLOOR, KER 200 or KER 800 grout (see data sheets for details). \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\b\i DO NOT}{\i specify for installations requiring high chemical or acid resistance. Specify KERAPOXY (see data sheet for details). \par }\pard \nowidctlpar\widctlpar\adjustright {\b\i \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\b\i DO NOT}{\i specify to grout non-vitreous glazed wall tile or polished marble. Specify KER 800 grout (see data sheet for details). \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {\i When specifying 2 \'bd to 1 in the Tile Section selected \endash ceramic tile \endash add appropriate articles or paragraphs under the applicable }{\b\i PART}{\i as indicated.}{ \par }\pard \nowidctlpar\widctlpar\adjustright {* \par }\pard\plain \s2\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {PART 1 GENERAL \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }\pard\plain \s3\li720\keepn\nowidctlpar\widctlpar\outlinelevel2\adjustright \b\fs20\cgrid {REFERENCES \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }\pard \li720\nowidctlpar\widctlpar\adjustright {ANSI A108.10 \endash Installation Specification for Grout in Tile Work \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par }\pard \li720\nowidctlpar\widctlpar\adjustright {ANSI A118.6 \endash Material Specification for Ceramic Tile Grout \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {ANSI A137.1 \endash Material Specification for Ceramic Tile \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Tile Council of America, Inc. (TCA) \endash Handbook for Ceramic Tile Installation \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par }\pard\plain \s3\li720\keepn\nowidctlpar\widctlpar\outlinelevel2\adjustright \b\fs20\cgrid {SUBMITTALS \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Product Data: Submit manufacturer\rquote s technical information and installation instructions for materials required. \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par }\pard\plain \s3\li720\keepn\nowidctlpar\widctlpar\outlinelevel2\adjustright \b\fs20\cgrid {QUALITY ASSURANCE \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {Provide tile, grout and setting materials from one source. Additives, dry-set mortars, installation materials and grouts shall be from the same manufacturer. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }\pard\plain \s3\li720\keepn\nowidctlpar\widctlpar\outlinelevel2\adjustright \b\fs20\cgrid {DELIVERY, STORAGE AND HANDLING \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Deliver and store packaged materials in original containers with seals unbroken and labels intact until time of use. Prevent damage or contamination to materials by water, freezing, foreign matter or other causes. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Deliver and store materials on site at least 24 hours before work begins. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Provide heated and dry storage facilities on site. \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par }\pard\plain \s3\li720\keepn\nowidctlpar\widctlpar\outlinelevel2\adjustright \b\fs20\cgrid {PROJECT CONDITIONS \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Maintain environmental conditions and protect work during and after installation to comply with referenced standards and manufacturer\rquote s printed recommendations. \par }\pard \nowidctlpar\widctlpar\adjustright { \par * \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {Environmental conditions may have an effect on the final color of Portland cement grouts. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {* \par \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {Vent temporary heaters to exterior to prevent damage to tilework from carbon dioxide build-up. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Maintain temperature at not less than 50 degrees F (10 degrees C) in tiled areas during installation and for 7 days after completion, unless higher temperatures are required by referenced installation standards or manufacturer\rquote s written instructions. \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par PART 2 PRODUCTS \par }{ \par }\pard\plain \s2\li720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {GROUT MATERIALS \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\i \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {GROUT: 2 1/2 to 1 Large Joint Filler/ Sautillo Grout, sanded as manufactured by MAPEI CORPORATION. \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid { \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\i *}{\b \par }{\i When specifying 2 1/2 to 1 Grout in performance specification, Call MAPEI CORPORATION\rquote s Technical Service Department toll-free number for assistance with product characteristics}{.}{\i \par \par When specifying a latex grout additive with 2 1/2 to 1 Grout, specify PLASTIJOINTS acrylic latex grout additive (see specification sheet). \par \par When specifying MORTARS or ADHESIVE MATERIALS, refer to respective suggested mortar or adhesive specification. \par }{* \par \par }\pard\plain \s2\fi720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {MIXES \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\b \par }\pard \li720\nowidctlpar\widctlpar\adjustright {Proportion and mix factory-prepared mortar with acrylic latex additive in accordance with manufacturer\rquote s printed instructions. \par }\pard \nowidctlpar\widctlpar\adjustright {\b \par PART 3 EXECUTION \par \par }{* \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {Specifications for surface conditions are listed in the beginning of the specification of MAPEI\rquote s Architectural Binder. These specifications should be called out with the related work sections. Delete non-applicable conditions. (Refer to ANSI EXPLANATION AND NOTES section: AN-3 RELATED WORK SPECIFIED IN OTHER SECTIONS.) \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {* \par \par }\pard\plain \s2\fi720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {EXAMINATION \par }\pard\plain \li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par Examine surfaces to receive tilework and conditions under which tile will be installed. Do not proceed with tilework until surfaces and conditions comply with requirements indicated in reference tile installation standards and manufacturer\rquote s printed instructions. \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard\plain \s2\fi720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {INSTALLATION \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {Grout tile in accordance with manufacturer\rquote s printed instructions and ANSI A108.10. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par * \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {Select TCA method to be used and delete non-applicable methods. (Select from latest edition of the TCA Handbook.) \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\i * \par }{ \par }\pard \li720\nowidctlpar\widctlpar\adjustright {[Floor Tile: Install in accordance with TCA method \par [F101], [F102], [F103], [F111], [F112], [F113], [F116], \par [F121], [F122], [F141], [F144], [TR712], [RF912].] \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {[Wall Tile: Install in accordance with TCA method \par [W201], [W202], [W211], [W221], [W222], [W231], [W241], \par [W242], [W243], [W244], [B411], [B412], [B413], [B414], [B415], \par [B416], [B417], [TR711], [TR713].] \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {[Ceiling or Soffit Tile: Install in accordance with TCA method C311.] \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {[Countertop Tile: Install in accordance with TCA method [C511], [C512], [C513].] \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {[Swimming Pool Tile: Install in accordance with TCA method P601.] \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {[Tub and Fountain Tile: Install in accordance with TCA method B417.] \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {[Stair Tile: Install in accordance with TCA method S151.] \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {Install expansion and control joints in accordance with TCA method EJ171. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {Grout joints shall be clean and free from standing water, dust and foreign substances. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par }\pard\plain \s17\li720\nowidctlpar\widctlpar\adjustright \fs20\cgrid {Tile surfaces shall be clean and dry. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par * \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {Add appropriate statement to installation. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {\i \par If PLASTIJOINTS has not been specified with the 2 1/2 to 1 Grout, that it is recommended to damp cure the grout for the first 72 hours after installation. Damp curing can be accomplished by misting the grout surface with water or covering with a natural kraft paper. (Do not use plastic sheeting or newspaper). \par }{* \par }\pard\plain \s2\fi720\keepn\nowidctlpar\widctlpar\outlinelevel1\adjustright \b\fs20\cgrid {PROTECTION \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid { \par * \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {Select appropriate statements for installation \endash floor, wall or both. Delete non-applicable statements. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {* \par }\pard \li720\nowidctlpar\widctlpar\adjustright {[Protect floors from general traffic for at least 72 hours after installatio n. Prohibit heavy traffic on floors for at least 7 days after installation. Plywood or stepping boards may be used after 24 hours when occasional stepping on the floor is unavoidable.] \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \li720\nowidctlpar\widctlpar\adjustright {[Protect walls from impact, vibration and heavy hammering on adjacent and opposite walls for at least 14 days after installation.] \par }\pard \nowidctlpar\widctlpar\adjustright { \par }\pard \fi720\nowidctlpar\widctlpar\adjustright {Protect from freezing and total water immersion for at least 21 days after installation. \par }\pard \nowidctlpar\widctlpar\adjustright { \par * \par }\pard\plain \s15\nowidctlpar\widctlpar\adjustright \i\fs20\cgrid {When dealing wi th cement-based products, it should be noted that temperature and humidity during and after installation of tile affect final curing time, i.e., low temperatures (60 degrees and under) and high humidity (70% and above) will delay final cure time. \par }\pard\plain \nowidctlpar\widctlpar\adjustright \fs20\cgrid {* \par \par For further information and technical assistance, contact: \par \par \par }\pard \sa120\nowidctlpar\widctlpar\adjustright {\tab \tab \tab \tab MAPEI CORPORATION \par \tab \tab \tab \tab 1501 WALL STREET \par \tab \tab \tab \tab GARLAND, TEXAS 75041-4046 \par \tab \tab \tab \tab 1-800-992-6273 \par }}