Sto Corp. Featured In Walls & Ceilings; Entitled Moisture Control (Easy as 3-4-5)

 

The ways of defeating water have changed over the years but the core concepts that have always worked are still being used ... along with a few new steps.

Understanding the “Leak Triangle” and utilizing the 3-D approach—deflect, drain and dry— will enable the design/construction team to be more effective in analyzing problems and recommending solutions. Building the four lines of defense into a wall assembly and incorporating details to handle the five forces that bring water into a wall will help to ensure a dry wall.

LEAK TRIANGLE

For a leak to occur, three things are required: water, a hole or path through the cladding and a force to move water through the hole. Take away any one and no leak can occur.

Thus, obviously, if there is no water or path, there will be no leak.Less obvious is the role of “force.” If there is no force, then even if water and a hole are present, there will not be a leak (Figure 1).

THE 3-D APPROACH: DEFLECT, DRAIN, DRY

Probably the first and most basic principle to remember from the “3-D approach” is to deflect. This is something we’ve known about since childhood. What do we do when it rains? We open an umbrella and deflect the water away from us. If you can deflect water away from potential sources of water penetration, you have removed “water” from the leak triangle.

The same principle applies to buildings. Houses normally have roof overhangs to deflect rainwater away from the walls. This is not a new concept, although its prime importance in protecting buildings often appears to have been forgotten. Medieval cathedrals, an early version of highrise structures, were adorned with gargoyles. Besides frightening the sin out of true believers, they deflected water from high up on the structure by spewing it away from the walls.This is essentially the same function as gutters and downspouts on houses, although the results were a lot more visually interesting (Figure 2).

Deflection works on a smaller scale as well. We install flashings in walls and above windows to deflect water away from openings. Flashings should always project far enough out to ensure that water will drip past the outer surface of the wall.

Overhangs deflect water effectively on low-rise non-commercial buildings.Gargoyles, however, may never make a comeback in modern high-rise construction. So what can be done to protect taller buildings where walls are more exposed? If we can’t keep water off the walls, then we need to think about multiple lines of defense to protect against rainwater penetration.

“Drainage” is the second in the 3-D approach to controlling water penetration. If water gets in the wall it should have a clear path through the drainage cavity to get out. That is typically the space between the back side of the cladding and the water resistive barrier.

Finally, any water or high humidity within the cladding or drainage cavity should have the opportunity to dry. Highly water absorptive claddings like brick or stucco may dry towards the interior when the sun shines on the wall. In those cases, a good ventilation cavity is important to allow the wall to dry.

THE FOUR LINES OF DEFENSE

There are four basic lines of defense in a wall assembly that are important in keeping the wall dry (Figure 3):

1. The outermost water-shedding surface
2. The innermost plane of water penetration
3. The air barrier
4. The vapor control You can always add more measures, but these four are the main lines of defense. The first three control rain penetration. The fourth reduces condensation and allows drying.

The outermost water-shedding surface of a cladding is intended to keep all water from entering the wall. If that surface has:

  • Materials that don’t leak
  • Windows and penetrations that don’t leak
  • Sealant connections that don’t leak
  • An owner who practices systematic maintenance to ensure that none of the above three components begin to leak over time ... then you have a perfect barrier wall.

Barrier walls can and have functioned well but as a strategy for providing long-term performance of the wall assembly, other options should be considered. This is especially true if any of the above conditions will not be met. We turn therefore to the multiple line of defense strategy.

The water-shedding surface is the first line of defense. Its performance should control at least 98 percent of the water that strikes the wall. After that, all we have to deal with is the 2 percent or less that is not deflected.This water may find a way around the cladding, and while 2 percent may not seem like much, if it occurs at the same location and is chronic, then progressive damage may occur if not repaired.

The second line of defense or water-resistive barrier is the last chance to control the water and it has to be fail-proof. How do we do that?

The water penetration barrier must be not only waterproof but also continuous. Water that passes the outer cladding has to drain freely to the flashing in order to drain out of the wall. As the water drains, it is imperative that none penetrates further into the building. All of the components of the water-resistive barrier must be correctly connected to ensure that there are no gaps or blockage (Figure 3).

An air barrier is required by code to control energy. While air moving through building enclosures costs the U.S. up to 40 percent of overall energy consumption—hence the energy code requirements—an air barrier also controls bulk water entry. Ever pinch a straw tight while trying to drink through it? You created an air barrier. Air cannot move through the straw and water will not move up the straw. This removes pressure difference as one of the five forces in the leak triangle.

FIVE FORCES

The five forces that move water through a hole are gravity, kinetic energy, surface tension, capillary movement and pressure difference.We can’t overcome the forces of nature, but we can work with them.

  • Gravity is overcome with flashing and by allowing drainage to the exterior at the bottom of a cavity.
  • Kinetic energy is typically controlled by placing a cover over an opening. For example, we shut the window when it starts to rain.
  • Surface tension is broken by adding a drip edge to ledges.
  • Capillary movement is stopped by adding a chamber—a capillary break.
  • Pressure difference, caused largely by wind pressure, is controlled by adding an air barrier to the wall.

John Edgar is technical manager of building science for Sto Corp.

For other relevant searches, you might want to try:

(01560) Temporary Barriers and Enclosures
(02 - 16 Div.) Site Construction
(02070) Geosynthetic
(02620) Subdrainage
(03330) Architectural Concrete
(03350) Concrete Finishing
(03360) Concrete Finishes
(03530) Concrete Topping
(07200) Thermal Protection
(07270) Air Barrier
(07710) Manufactured Roof Specialties
(09960) High-Performance Coating
  (01 56 13) Temporary Air Barriers
(03 33 00) Architectural Concrete
(03 35 00) Concrete Finishing
(03 53 00) Concrete Topping
(07 20 00) Thermal Protection
(07 27 00) Air Barriers
(07 71 00) Roof Specialties
(07 77 00) Wall Specialties
(09 96 00) High-Performance Coatings
(32) Exterior Improvements
(33 46 00) Subdrainage
(41 61 00) Mobile Earth Moving Equipment