StoneLite Panels Successfully Pass NFPA 285 Standard for an Open Joint System
Other News Subscribe to FREE newsletter | Feb 17, 2015 |
Stone Panels International LLC is pleased to announce that our ³§³Ù´Ç²Ô±ð³¢¾±³Ù±ð® product has been tested and approved to the 2012 NFPA 285 fire standard for an open joint (rainscreen) system. Testing was performed at an accredited facility on June 19th, 2014 to the National Fire Protection Association 285, Standard Fire Test for Evaluation of Fire Propagation Characteristics of Exterior Nonload-Bearing Wall Assemblies Containing Combustible Components, 2012 Edition.
This achievement provides our clients with a light weight natural stone product to be used in designs meeting the NFPA 285 standards reflected in the California Code of Regulations (CRR) Title 24.
The primary performance characteristics evaluated were:
- Flame propagation over the exterior face of the system
- Vertical flame spread within the combustible core components from one story to the next
- Vertical flame spread over the interior (room side) surface of the panels from one story to the next
- Lateral flame spread from the compartment of the fire origin to adjacent spaces
- 5/8” thick Type X Gypsum
- 3-5/8” 16-ga steel studs on 24” spacing
- ½” thick Densglass Gold sheathing
- Mineral wool floor line safing (4 pcf)
- Henry Blueskin Self Adhering Waterproofing Membrane
- 5x2x1/8 in. thick aluminum flashing
- 25 mm extruded aluminum furring channels by Nvelope USA
- 2” thick Thermafiber mineral wool continues insulation (CI)
- ³§³Ù´Ç²Ô±ð³¢¾±³Ù±ð® panels and aluminum attachment system